Evidence map›Paper›PMID 36355631›Full record

ArticleJournal of biomedical materials research. Part A2023

A comparative high-resolution physicochemical analysis of commercially available fibrin sealants: Impact of sealant osmolality on biological performance.

Raffael Reichsöllner, Philipp Heher, Jaana Hartmann, Stefan Manhartseder, Rahul Singh, Heinz Gulle, Paul Slezak

Open access · hybridAbstract read
In one paragraph

Article in Journal of biomedical materials research. Part A, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.0field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 3 countries.

Raffael ReichsöllnerLudwig Boltzmann Institute for Traumatology, The Research Center in Cooperation with AUVA, Vienna, Austria.
Philipp HeherRandall Centre for Cell and Molecular Biophysics, King's College London, London, UK.ORCID 0000-0002-6722-5875
Jaana HartmannLudwig Boltzmann Institute for Traumatology, The Research Center in Cooperation with AUVA, Vienna, Austria.
Stefan ManhartsederLudwig Boltzmann Institute for Traumatology, The Research Center in Cooperation with AUVA, Vienna, Austria.
Rahul SinghBaxter International Inc., Deerfield, Illinois, USA.
Heinz GulleBaxter International Inc., Deerfield, Illinois, USA.
Paul SlezakLudwig Boltzmann Institute for Traumatology, The Research Center in Cooperation with AUVA, Vienna, Austria.
Ludwig Boltzmann Institute for Traumatology, The Research Center in Cooperation with AUVA · ATBaxter (United States) · USKing's College London · GB

Funding

Baxter Healthcare Corporation
6 · The paper itself

Abstract

Fibrin sealants are well-established components of the surgical toolbox, especially in procedures that harbor a high risk of perioperative bleeding. Their widespread use as hemostats, sealants or tissue-adhesives in various surgical settings has shown that the choice of the appropriate sealant system affects the clinical outcome. While many studies have compared the hemostatic efficiency of fibrin sealants to that of other natural or synthetic sealants, there is still limited data on how subtle differences in fibrin sealant formulations relate to their biological performance. Here, we performed an in-depth physicochemical and biological characterization of the two most commonly used fibrin sealants in the US and Europe: TISSEEL™ ("FS") and VISTASEAL™/VERASEAL™ ("FS+Osm"). Our chemical analyses demonstrated differences between the two sealants, with lower fibrinogen concentrations and supraphysiological osmolality in the FS+Osm formulation. Rheological testing revealed FS clots have greater clot stiffness, which strongly correlated with network density. Ultrastructural analysis by scanning electron microscopy revealed differences between FS and FS+Osm fibrin networks, the latter characterized by a largely amorphous hydrogel structure in contrast to the physiological fibrillar network of FS. Cytocompatibility experiments with human fibroblasts seeded on FS and FS+Osm fibrin networks, or cultured in presence of sealant extracts, revealed that FS+Osm induced apoptosis, which was not observed with FS. Although differential sealant osmolality and amounts of fibrinogen, as well as the presence of Factor XIII or additives such as antifibrinolytics, may explain the mechanical and structural differences observed between the two fibrin sealants, none of these substances are known to cause apoptosis at the respective concentrations in the sealant formulation. We thus conclude that hyper osmolality in the FS+Osm formulation is the primary trigger of apoptosis-a mechanism that should be evaluated in more detail, as it may affect the cellular wound healing response in situ.

Indexed as

HemostaticsTissue AdhesivesFibrinogenFibrin Tissue AdhesiveHumansWound HealingFibrinogenFibrin Tissue AdhesiveHemostaticsTissue Adhesivescytocompatibilityfibrin sealantosmolalityTISSEELVERASEALVISTASEAL

Identifiers

PMID36355631
PMCPMC10099741
OpenAlexW4308681890

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked