Evidence map›Paper›PMID 36354532›Full record

ArticleBioengineering (Basel, Switzerland)2022

Biocompatibility and Connectivity of Semiconductor Nanostructures for Cardiac Tissue Engineering Applications.

Roberto Gaetani, Yuriy Derevyanchuk, Andrea Notargiacomo, Marialilia Pea, Massimiliano Renzi, Elisa Messina, Fabrizio Palma

Open access · goldAbstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 50% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 4 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Roberto GaetaniDepartment of Molecular Medicine, "Sapienza" University of Rome, 00176 Rome, Italy.ORCID 0000-0001-5667-5152
Yuriy DerevyanchukDepartment of Molecular Medicine, "Sapienza" University of Rome, 00176 Rome, Italy.
Andrea NotargiacomoInstitute for Photonics and Nanotechnologies (IFN), National Research Council of Italy, 00133 Rome, Italy.
Marialilia PeaInstitute for Photonics and Nanotechnologies (IFN), National Research Council of Italy, 00133 Rome, Italy.
Massimiliano RenziDepartment of Physiology and Pharmacology, "Sapienza" University of Rome, 00176 Rome, Italy.ORCID 0000-0001-6973-3569
Elisa MessinaPoliclinico Umberto I, "Sapienza" University of Rome, 00176 Rome, Italy.ORCID 0000-0002-1654-9001
Fabrizio PalmaDepartment Ingegneria dell' Informazione, Elettronica e Telecomunicazioni, "Sapienza" University of Rome, 00176 Rome, Italy.ORCID 0000-0002-4331-3547
Sapienza University of Rome · ITCenter for Biomolecular Nanotechnologies · ITInstitute of Electronics, Computer and Telecommunication Engineering · ITPoliclinico Umberto I · IT

Funding

Sapienza University of Rome RM120172B7F71B4B
6 · The paper itself

Abstract

Nano- or microdevices, enabling simultaneous, long-term, multisite, cellular recording and stimulation from many excitable cells, are expected to make a strategic turn in basic and applied cardiology (particularly tissue engineering) and neuroscience. We propose an innovative approach aiming to elicit bioelectrical information from the cell membrane using an integrated circuit (IC) bearing a coating of nanowires on the chip surface. Nanowires grow directly on the backend of the ICs, thus allowing on-site amplification of bioelectric signals with uniform and controlled morphology and growth of the NWs on templates. To implement this technology, we evaluated the biocompatibility of silicon and zinc oxide nanowires (NWs), used as a seeding substrate for cells in culture, on two different primary cell lines. Human cardiac stromal cells were used to evaluate the effects of ZnO NWs of different lengths on cell behavior, morphology and growth, while BV-2 microglial-like cells and GH4-C1 neuroendocrine-like cell lines were used to evaluate cell membrane-NW interaction and contact when cultured on Si NWs. As the optimization of the contact between integrated microelectronics circuits and cellular membranes represents a long-standing issue, our technological approach may lay the basis for a new era of devices exploiting the microelectronics' sensitivity and "smartness" to both improve investigation of biological systems and to develop suitable NW-based systems available for tissue engineering and regenerative medicine.

Indexed as

biocompatibilitycardiac tissueelectronic sensingsilicon nanowireszinc oxide nanowires

Identifiers

PMID36354532
PMCPMC9687646
OpenAlexW4307437001

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.