ArticleBiosensors2022
Comparison of Optical and Electrical Sensor Characteristics for Efficient Analysis of Attachment and Detachment of Aptamer.
Article in Biosensors, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Review
- A Novel Pathogen Detection System Combining a Nucleic Acid Extraction Biochip with a Perovskite Photodetector.Micromachines · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Nucleic acid aptamer-based research has focused on achieving the highest performance for bioassays. However, there are limitations in evaluating the affinity for the target analytes in these nucleic acid aptamer-based bioassays. In this study, we mainly propose graphene oxide (GO)-based electrical and optical analyses to efficiently evaluate the affinity between an aptamer and its target. We found that an aptamer-coupled GO-based chip with an electrical resistance induced by a field-effect transistor, with aptamers as low as 100 pM, can detect the target, thrombin, at yields as low as 250 pM within five minutes. In the optical approach, the fluorescent dye-linked aptamer, as low as 100 nM, was efficiently used with GO, enabling the sensitive detection of thrombin at yields as low as 5 nM. The cantilever type of mechanical analysis also demonstrated the intuitive aptamer-thrombin reaction in the signal using dBm units. Finally, a comparison of electrical and optical sensors' characteristics was introduced in the attachment and detachment of aptamer to propose an efficient analysis that can be utilized for various aptamer-based research fields.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.