Evidence map›Paper›PMID 36354451›Full record

ArticleBiosensors2022

Ultrasensitive Fluorescence Lateral Flow Assay for Simultaneous Detection of

Zhijie Tu, Xingsheng Yang, Hao Dong, Qing Yu, Shuai Zheng, Xiaodan Cheng, Chongwen Wang, Zhen Rong, Shengqi Wang

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 31 citations in OpenAlex.

  1. Review
  2. Review
  3. A Novel Aptamer Selection Strategy forMolecules (Basel, Switzerland) · 2025
    Article
  4. Review
  5. Review
  6. Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 1 country.

Zhijie TuBeijing Institute of Microbiology and Epidemiology, Beijing 100089, China.
Xingsheng YangBeijing Institute of Microbiology and Epidemiology, Beijing 100089, China.
Hao DongScience Island Branch of Graduate School, University of Science and Technology of China, Hefei 230036, China.
Qing YuBeijing Institute of Microbiology and Epidemiology, Beijing 100089, China.
Shuai ZhengScience Island Branch of Graduate School, University of Science and Technology of China, Hefei 230036, China.
Xiaodan ChengBeijing Institute of Microbiology and Epidemiology, Beijing 100089, China.
Chongwen WangBeijing Institute of Microbiology and Epidemiology, Beijing 100089, China.ORCID 0000-0002-9627-107X
Zhen RongBeijing Institute of Microbiology and Epidemiology, Beijing 100089, China.
Shengqi WangBeijing Institute of Microbiology and Epidemiology, Beijing 100089, China.
Institute of Microbiology · CNAnhui Agricultural University · CNUniversity of Science and Technology of China · CNXuzhou Medical College · CN

Funding

National Natural Science Foundation of China 81830101, 32200076
6 · The paper itself

Abstract

Point-of-care testing methods for the rapid and sensitive screening of pathogenic bacteria are urgently needed because of the high number of outbreaks of microbial infections and foodborne diseases. In this study, we developed a highly sensitive and multiplex lateral flow assay (LFA) for the simultaneous detection of Pseudomonas aeruginosa and Salmonella typhimurium in complex samples by using wheat germ agglutinin (WGA)-modified magnetic quantum dots (Mag@QDs) as a universal detection nanoprobe. The Mag@QDs-WGA tag with a 200 nm Fe3O4 core and multiple QD-formed shell was introduced into the LFA biosensor for the universal capture of the two target bacteria and provided the dual amplification effect of fluorescence enhancement and magnetic enrichment for ultra-sensitivity detection. Meanwhile, two antibacterial antibodies were separately sprayed onto the two test lines of the LFA strip to ensure the specific identification of P. aeruginosa and S. typhimurium through one test. The proposed LFA exhibited excellent analytical performance, including high capture rate (>80%) to the target pathogens, low detection limit (<30 cells/mL), short testing time (<35 min), and good reproducibility (relative standard deviation < 10.4%). Given these merits, the Mag@QDs-WGA-based LFA has a great potential for the on-site and real-time diagnosis of bacterial samples.

Indexed as

Quantum DotsImmunoassayPseudomonas aeruginosaReproducibility of ResultsSalmonella typhimuriumWheat Germ AgglutininsWheat Germ Agglutininsmagnetic quantum dotmultiplex LFAPseudomonas aeruginosaSalmonella typhimuriumwheat germ agglutinin

Identifiers

PMID36354451
PMCPMC9687718
OpenAlexW4307855361

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.