Evidence map›Paper›PMID 36351067›Full record

ArticleRevista Brasileira de terapia intensiva2022

Robust, maintainable, emergency invasive mechanical ventilator.

Paulo J R Fonte, Alberto Martinho, Américo Pereira, Andreia Gomes, Ângela Neves, Antero Abrunhosa, António Bugalho, António Gabriel-Santos, António Grilo, Carlos Carmo and 17 more

Open access · diamondAbstract read
In one paragraph

Article in Revista Brasileira de terapia intensiva, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 75% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

27 authors at 11 institutions in 2 countries.

Paulo J R FonteICNAS Pharma - Instituto de Ciências Nucleares Aplicadas à saúde, Universidade de Coimbra - Coimbra, Portugal.ORCID http://orcid.org/0000-0002-2275-9099
Alberto MartinhoUNIDEMI - Department of Mechanical and Industrial Engineering, NOVA School of Science and Technology, Universidade Nova de Lisboa - Caparica, Portugal.ORCID http://orcid.org/0000-0002-1137-9373
Américo PereiraLIP - Laboratório de Instrumentação e Física Experimental de Partículas - Coimbra, Portugal.
Andreia GomesCIBIT - Centro de Imagem Biomédica e Investigação Translacional, Universidade de Coimbra - Coimbra, Portugal.ORCID http://orcid.org/0000-0003-0481-0812
Ângela NevesICNAS Pharma - Instituto de Ciências Nucleares Aplicadas à saúde, Universidade de Coimbra - Coimbra, Portugal.ORCID http://orcid.org/0000-0001-8355-9536
Antero AbrunhosaICNAS Pharma - Instituto de Ciências Nucleares Aplicadas à saúde, Universidade de Coimbra - Coimbra, Portugal.ORCID http://orcid.org/0000-0002-4145-854X
António BugalhoCHRC - Centro de Investigação Integrada em Saúde, Nova Medical School, Universidade Nova de Lisboa - Lisboa, Portugal.ORCID http://orcid.org/0000-0003-3951-1134
António Gabriel-SantosUNIDEMI - Department of Mechanical and Industrial Engineering, NOVA School of Science and Technology, Universidade Nova de Lisboa - Caparica, Portugal.ORCID http://orcid.org/0000-0002-1797-2020
António GriloUNIDEMI - Department of Mechanical and Industrial Engineering, NOVA School of Science and Technology, Universidade Nova de Lisboa - Caparica, Portugal.ORCID http://orcid.org/0000-0002-6045-9994
Carlos CarmoMagnamed - Comercialização de Produtos Médicos, Lda - Lisboa, Portugal.
Elsa MaltezICNAS Pharma - Instituto de Ciências Nucleares Aplicadas à saúde, Universidade de Coimbra - Coimbra, Portugal.ORCID http://orcid.org/0000-0002-2732-5804
João Agostinho do NascimentoMédicos do Mundo - Lisboa, Portugal.ORCID http://orcid.org/0000-0001-7725-0559
João GoesDepartamento de Engenharia Electrotécnica e de Computadores, Centro de Tecnologia e Sistemas, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa - Caparica, Portugal.ORCID http://orcid.org/0000-0002-8434-8391
João MartinsDepartamento de Engenharia Electrotécnica e de Computadores, Centro de Tecnologia e Sistemas, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa - Caparica, Portugal.ORCID http://orcid.org/0000-0002-2248-2595
João Pedro OliveiraDepartamento de Engenharia Electrotécnica e de Computadores, Centro de Tecnologia e Sistemas, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa - Caparica, Portugal.ORCID http://orcid.org/0000-0003-3396-4634
Jorge PimentaInstituto Nacional de Investigação Agrária e Veterinária, I. P. - Oeiras, Portugal.ORCID http://orcid.org/0000-0002-3796-0238
José Paulo SantosLaboratório de Instrumentação, Engenharia Biomédica e Física das Radiações, Departamento de Física, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa - Caparica, Portugal.ORCID http://orcid.org/0000-0002-5890-0971
Luís C GilUNIDEMI - Department of Mechanical and Industrial Engineering, NOVA School of Science and Technology, Universidade Nova de Lisboa - Caparica, Portugal.ORCID http://orcid.org/0000-0001-8129-5741
Luís LopesLIP - Laboratório de Instrumentação e Física Experimental de Partículas - Coimbra, Portugal.ORCID http://orcid.org/0000-0001-8571-0033
Mário PimentaLIP - Laboratório de Instrumentação e Física Experimental de Partículas - Coimbra, Portugal.ORCID http://orcid.org/0000-0002-2590-0908
Olga MoreiraInstituto Nacional de Investigação Agrária e Veterinária, I. P. - Oeiras, Portugal.ORCID http://orcid.org/0000-0002-1271-4823
Orlando CunhaLIP - Laboratório de Instrumentação e Física Experimental de Partículas - Coimbra, Portugal.ORCID http://orcid.org/0000-0002-5674-4346
Pedro Pinheiro de SousaHaas F1 Team - Maranello, Italia.
Pedro PóvoaCHRC - Centro de Investigação Integrada em Saúde, Nova Medical School, Universidade Nova de Lisboa - Lisboa, Portugal.ORCID http://orcid.org/0000-0002-7069-7304
Sandra Cavaco-GonçalvesInstituto Nacional de Investigação Agrária e Veterinária, I. P. - Oeiras, Portugal.ORCID http://orcid.org/0000-0003-1280-229X
Susana BarrosoICNAS Pharma - Instituto de Ciências Nucleares Aplicadas à saúde, Universidade de Coimbra - Coimbra, Portugal.ORCID http://orcid.org/0000-0002-8806-218X
Telmo G SantosUNIDEMI - Department of Mechanical and Industrial Engineering, NOVA School of Science and Technology, Universidade Nova de Lisboa - Caparica, Portugal.ORCID http://orcid.org/0000-0001-9072-5010
Universidade Nova de Lisboa · PTLIP - Laboratory of Instrumentation and Experimental Particle Physics · PTUniversity of Coimbra · PTOrdem dos Médicos · PTUniversity of Lisbon · PTAssociation for Innovation and Biomedical Research on Light and Image · PTCentro Hospitalar de Lisboa Ocidental · PTCUF Porto Hospital · PTHospitais da Universidade de Coimbra · PTIdaho Academy of Science · USInstituto Nacional de Investigação Agrária e Veterinária · PT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo develop a simple, robust, safe and efficient invasive mechanical ventilator that can be used in remote areas of the world or war zones where the practical utility of more sophisticated equipment is limited by considerations of maintainability, availability of parts, transportation and/or cost.

methodsThe device implements the pressure-controlled continuous mandatory ventilation mode, complemented by a simple assist-control mode. Continuous positive airway pressure is also possible. The consumption of compressed gases is minimized by avoiding a continuous flow of oxygen or air. Respiratory rates and inspiration/expiration time ratios are electronically determined, and an apnea/power loss alarm is provided.

resultsThe pressure profiles were measured for a range of conditions and found to be adjustable within a ± 2.5cmH2O error margin and stable well within this range over a 41-hour period. Respiratory cycle timing parameters were precise within a few percentage points over the same period. The device was tested for durability for an equivalent period of four months. Chemical and biological tests failed to identify any contamination of the gas by volatile organic compounds or microorganisms. A ventilation test on a large animal, in comparison with a well established ventilator, showed that the animal could be adequately ventilated over a period of 60 minutes, without any noticeable negative aftereffects during the subsequent 24-hour period.

conclusionThis ventilator design may be viable, after further animal tests and formal approval by the competent authorities, for clinical application in the abovementioned atypical circumstances.

Indexed as

Continuous Positive Airway PressureVentilators, MechanicalAnimalsHumansRespiration, Artificial

Identifiers

PMID36351067
PMCPMC9749093
OpenAlexW4308772229

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.