Evidence map›Paper›PMID 36349872›Full record

ArticleOrthopaedic surgery2023

Canceling Notch Improves the Mechanical Safety of Clavicle Locking Plate: A 3D Finite Element Study.

Zhihua Han, Qian Luo, Guoying Deng, Chun Bi, Gang Yin, Haodong Lin, Jianhong Wu, Xiaoming Wu

Abstract read
In one paragraph

Article in Orthopaedic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Zhihua HanTrauma Center, Department of Orthopaedics and Traumatology, Shanghai General Hospital, Shanghai Jiaotong University, Shanghai, China.ORCID https://orcid.org/0000-0003-3128-3077
Qian LuoDepartment of Radiology, Shanghai General Hospital, Shanghai Jiaotong University, Shanghai, China.
Guoying DengTrauma Center, Department of Orthopaedics and Traumatology, Shanghai General Hospital, Shanghai Jiaotong University, Shanghai, China.
Chun BiTrauma Center, Department of Orthopaedics and Traumatology, Shanghai General Hospital, Shanghai Jiaotong University, Shanghai, China.
Gang YinTrauma Center, Department of Orthopaedics and Traumatology, Shanghai General Hospital, Shanghai Jiaotong University, Shanghai, China.
Haodong LinTrauma Center, Department of Orthopaedics and Traumatology, Shanghai General Hospital, Shanghai Jiaotong University, Shanghai, China.ORCID https://orcid.org/0000-0001-5414-7516
Jianhong WuTrauma Center, Department of Orthopaedics and Traumatology, Shanghai General Hospital, Shanghai Jiaotong University, Shanghai, China.
Xiaoming WuTrauma Center, Department of Orthopaedics and Traumatology, Shanghai General Hospital, Shanghai Jiaotong University, Shanghai, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveImplant failure is a disastrous complication of the operative treatment of midshaft clavicle fractures, and improving the osteosynthesis plate is a strategy for preventing this. We aimed to investigate whether canceling the notch and adding screw-hole inserts enhanced the mechanical properties of the plate.

methodsA clavicle model was generated based on the CT images of six adult volunteers (age range, 20-40 years; three males and three females; height range 160-175) using dedicated software, and a midshaft fracture model was created. The domestically made seven-hole locking plate commonly used for midshaft clavicle fractures was simulated (Model I); modifications were made to the plate (Model II). Using 3D finite element analysis, we simulated the fracture construct under three different load conditions-downward cantilever bending, axial compression, and axial torsion-and compared the stress distribution.

resultsWe found that under axial compression, Model II experienced its maximum stress on the plate at 551.9MPa, which was less than that in Model I (790.4 MPa). Moreover, a greater stress concentration at the fracture site was observed under axial torsion, despite the maximum stress of both the models being similar.

conclusionCanceling the notch and filling the screw holes near the fracture can ameliorate stress concentration on the internal fixation construct and enhance its reliability under axial compression. This improvement has substantial effects on the mechanical properties of implants and potentially prevents implant failure. Modern osteosynthesis anatomical implants need to be improved.

Indexed as

ClavicleFractures, BoneAdultBiomechanical PhenomenaBone PlatesFemaleFinite Element AnalysisFracture Fixation, InternalHumansMaleReproducibility of ResultsYoung AdultBiomechanicsClavicle fractureFinite elementLocking plate

Identifiers

PMID36349872
PMCPMC10432472

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.