ArticleExpert systems with applications2023
Improved deep convolutional neural networks using chimp optimization algorithm for Covid19 diagnosis from the X-ray images.
Article in Expert systems with applications, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 126 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
126 citing papers in PubMed.
- Wasserstein Deep Convolutional GAN With Growth Optimizer for Multi-Modal Feature Extraction in Cardiovascular Diagnosis.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026Article
- Blackcap Optimization Algorithm (BCOA): A Novel Metaheuristic Algorithm for Global and Engineering Optimization Problems.Biomimetics (Basel, Switzerland) · 2026Article
- An adaptive oppositional grey wolf optimizer for complex engineering problems.Scientific reports · 2026Article
- Assessment of a modified Coronavirus Disease Optimization Algorithm for Parameter Estimation of Proton Exchange Membrane Fuel Cells.Scientific reports · 2026Article
- Heart rate optimizer: a novel bio-inspired metaheuristic algorithm.Scientific reports · 2026Article
- Comparative evaluation of natural language processing approaches with particle swarm optimized LightGBM for anomaly detection in cloud system logs.Scientific reports · 2026Article
- Multi-strategy enhanced black-winged kite algorithm and its engineering applications.Scientific reports · 2026Article
- Dance movement reconstruction via a 2D matrix model and Haute Monde Chimp Optimization.Scientific reports · 2026Article
- Leveraging haze-aware features for improved image clarity and detection accuracy with an optimized DCNN-YOLOv8 network.Scientific reports · 2026Article
- Adaptive and migration-enhanced tree seed algorithm for multi-threshold CT image segmentation and lung cancer recognition.PloS one · 2026Article
- Multiple trajectory optimization and control of robotic agents using hybrid fuzzy embedded artificial intelligence technique for multi target problems.Scientific reports · 2025Article
- NDFNGO: Enhanced Northern Goshawk Optimization Algorithm for Image Segmentation.Biomimetics (Basel, Switzerland) · 2025Article
- Machine learning analysis of oral solid dosage formulation solubility variations by adjusting pressure and temperature.Scientific reports · 2025Article
- Development and evaluation of hybrid harris hawks optimization algorithms for advanced engineering applications.Scientific reports · 2025Article
- An improved artemisinin algorithm for task allocation in heterogeneous robot systems for chemical inspection.Scientific reports · 2025Article
- An Enhanced Randomized Dung Beetle Optimizer for Global Optimization Problems.Biomimetics (Basel, Switzerland) · 2025Article
- A sterna migration algorithm-based efficient bionic engineering optimization algorithm.Scientific reports · 2025Article
- Comprehensive evaluation of optimization algorithms for medical image segmentation.Scientific reports · 2025Article
- A new hybrid neural network framework inspired by biological systems for advanced financial forecasting.Scientific reports · 2025Article
- Extraction of PEM fuel cell variables based on modified hippopotamus optimization algorithm.Scientific reports · 2025Article
66 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Applying Deep Learning (DL) in radiological images (i.e., chest X-rays) is emerging because of the necessity of having accurate and fast COVID-19 detectors. Deep Convolutional Neural Networks (DCNN) have been typically used as robust COVID-19 positive case detectors in these approaches. Such DCCNs tend to utilize Gradient Descent-Based (GDB) algorithms as the last fully-connected layers' trainers. Although GDB training algorithms have simple structures and fast convergence rates for cases with large training samples, they suffer from the manual tuning of numerous parameters, getting stuck in local minima, large training samples set requirements, and inherently sequential procedures. It is exceedingly challenging to parallelize them with Graphics Processing Units (GPU). Consequently, the Chimp Optimization Algorithm (ChOA) is presented for training the DCNN's fully connected layers in light of the scarcity of a big COVID-19 training dataset and for the purpose of developing a fast COVID-19 detector with the capability of parallel implementation. In addition, two publicly accessible datasets termed COVID-Xray-5 k and COVIDetectioNet are used to benchmark the proposed detector known as DCCN-Chimp. In order to make a fair comparison, two structures are proposed: i-6c-2 s-12c-2 s and i-8c-2 s-16c-2 s, all of which have had their hyperparameters fine-tuned. The outcomes are evaluated in comparison to standard DCNN, Hybrid DCNN plus Genetic Algorithm (DCNN-GA), and Matched Subspace classifier with Adaptive Dictionaries (MSAD). Due to the large variation in results, we employ a weighted average of the ensemble of ten trained DCNN-ChOA, with the validation accuracy of the weights being used to determine the final weights. The validation accuracy for the mixed ensemble DCNN-ChOA is 99.11%. LeNet-5 DCNN's ensemble detection accuracy on COVID-19 is 84.58%. Comparatively, the suggested DCNN-ChOA yields over 99.11% accurate detection with a false alarm rate of less than 0.89%. The outcomes show that the DCCN-Chimp can deliver noticeably superior results than the comparable detectors. The Class Activation Map (CAM) is another tool used in this study to identify probable COVID-19-infected areas. Results show that highlighted regions are completely connected with clinical outcomes, which has been verified by experts.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials