Evidence map›Paper›PMID 36348632›Full record

ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2024

Gianmarco Bernava, Olivier Brina, Philippe Reymond, Andrea Rosi, Jeremy Hofmeister, Hasan Yilmaz, Michel Muster, Zsolt Kulcsar, Karl-Olof Lovblad, Paolo Machi

Open access · hybridAbstract read
In one paragraph

Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Gianmarco BernavaDivision of Neuroradiology, Geneva University Hospitals, Geneva, Switzerland.ORCID 0000-0003-2037-5558
Olivier BrinaDivision of Neuroradiology, Geneva University Hospitals, Geneva, Switzerland.
Philippe ReymondDivision of Neuroradiology, Geneva University Hospitals, Geneva, Switzerland.
Andrea RosiDivision of Neuroradiology, Geneva University Hospitals, Geneva, Switzerland.
Jeremy HofmeisterDivision of Neuroradiology, Geneva University Hospitals, Geneva, Switzerland.
Hasan YilmazDivision of Neuroradiology, Geneva University Hospitals, Geneva, Switzerland.
Michel MusterDivision of Neuroradiology, Geneva University Hospitals, Geneva, Switzerland.
Zsolt KulcsarDivision of Neuroradiology, University Hospital of Zurich, Zurich, Switzerland.
Karl-Olof LovbladDivision of Neuroradiology, Geneva University Hospitals, Geneva, Switzerland.
Paolo MachiDivision of Neuroradiology, Geneva University Hospitals, Geneva, Switzerland.
University Hospital of Geneva · CHUniversity Hospital of Zurich · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSeveral variations of the combined thrombectomy technique for acute ischemic stroke using a stent retriever and aspiration catheter have been described. The aim of our study was to assess how the presence of the microcatheter and stent retriever affect the basic aspiration parameters, namely, flow rate and aspiration force, depending on their position within the aspiration catheter.

methodsTwo experimental set-ups were designed to assess changes in flow rate and aspiration force according to the position of the stent retriever and microcatheter within the aspiration catheter.

resultsThe transition of the stent retriever and microcatheter from the distal to proximal position resulted in a progressive increase in the flow rate, but with no impact on aspiration force. Additionally, the size of the stent retriever had no significant effect on flow rate changes and the reduction in flow rate was related to the microcatheter diameter. Negative pressure generated inside the aspiration catheter impacted on its distal segment located beyond the radiopaque marker, thus leading to its partial collapse. As a consequence, the measured aspiration force was lower than the theoretical aspiration force level for all tested aspiration catheters.

conclusionsIn our experimental model, the position of the stent retriever and microcatheter within the aspirator catheter affected the flow rate, but not the aspiration force. Negative pressure generated within the aspiration catheter appeared to determine a partial collapse of the distal segment that resulted in a less effective aspiration force than the theoretical aspiration force level.

Indexed as

CathetersStentsThrombectomyEquipment DesignHumansIn Vitro TechniquesIschemic StrokeSuctionstroke, aspiration catheter, stentriever, microcatheter

Identifiers

PMID36348632
PMCPMC11528783
OpenAlexW4308578934

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.