Evidence map›Paper›PMID 36348352›Full record

ArticleBMC musculoskeletal disorders2022

3D planning and patient specific instrumentation for intraarticular corrective osteotomy of trapeziometacarpal-, metacarpal and finger joints.

Method Kabelitz, Pascal Raffael Furrer, Sandro Hodel, Sandro Canonica, Andreas Schweizer

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Method KabelitzDepartment of Orthopedics, Balgrist University Hospital, University of Zurich, 8008, Zurich, Switzerland. kabelitz.method@gmail.com.
Pascal Raffael FurrerDepartment of Orthopedics, Balgrist University Hospital, University of Zurich, 8008, Zurich, Switzerland.
Sandro HodelDepartment of Orthopedics, Balgrist University Hospital, University of Zurich, 8008, Zurich, Switzerland.
Sandro CanonicaDepartment of Orthopedics, Balgrist University Hospital, University of Zurich, 8008, Zurich, Switzerland.
Andreas SchweizerDepartment of Hand Surgery, Balgrist University Hospital, University of Zurich, 8008, Zurich, Switzerland.
University of Zurich · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIntra-articular malunions of the finger can lead to deformity and loss of function and can be treated with intra-articular corrective osteotomies. The aim of this study was to evaluate radiographic joint congruency, feasibility and functional outcome of three-dimensional (3D) printed patient-specific instrumentation (PSI) for corrective osteotomies at the trapeziometacarpal and finger joints.

methodsComputer-tomography (CT) scans were acquired preoperatively for standard 3D planning, which was followed by calculation of cutting planes and the design of individualized bone surface contact drilling, sawing and reposition guides. Follow-up CT scans and clinical examinations (range of motion, grip strength) were performed. Postoperative complications were documented and patient-reported outcome measurements were assessed (Single Assessment Numeric Evaluation (SANE) score, brief Michigan Hand Questionnaire (MHQ)).

resultsTen patients (mean age 28.4 ± 12.8,range 13.8-51.3) years) were included with a mean follow-up of 21 ± 18 (3-59) months including seven osteotomies at the trapeziometacarpal or metacarpophalangeal joints and three at the proximal interphalangeal joint (PIP). All radiographic follow-up examinations showed the planned correction with good joint congruency and regular osseous consolidation. At the latest follow-up, the range of motion (ROM) increased and the average grip strength recovered to the level of the contralateral side. No postoperative complication was detected. The mean SANE score improved from 44 ± 23 (0-70) to 82 ± 12 (60-90) after a mean of 72 ± 20 (44-114) months. The mean postoperative brief MHQ was 92 ± 8 (71-98).

conclusionThe use of 3D PSI in treating intra-articular malunions at the trapeziometacarpal and finger joints restored articular congruency accurately. ROM and grip strength improved postoperatively comparable to the healthy contralateral side and patient-reported outcome measures improved after medium-term follow-up.

Indexed as

Fractures, MalunitedMetacarpal BonesChild, PreschoolFinger JointHumansInfantOsteotomyRange of Motion, ArticularCorrectionFinger osteotomyIntra-articularOsteotomyPatient-specific instrumentation

Identifiers

PMID36348352
PMCPMC9641882
OpenAlexW4308595013

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.