Evidence map›Paper›PMID 36348287›Full record

ArticleBMC medical imaging2022

Reproducibility and repeatability of a semi-automated pipeline to quantify trapeziometacarpal joint angles using dynamic computed tomography.

Michael T Kuczynski, Kendra Wang, Justin J Tse, Tomasz Bugajski, Sarah L Manske

Open access · goldAbstract read
In one paragraph

Article in BMC medical imaging, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 74% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 0 citations in OpenAlex.

  1. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Michael T KuczynskiBiomedical Engineering Graduate Program, Schulich School of Engineering, University of Calgary, Calgary, Canada.
Kendra WangMcCaig Institute for Bone and Joint Health, University of Calgary, 3280 Hospital Drive, N.W., Calgary, AB, T2N 4Z6, Canada.
Justin J TseMcCaig Institute for Bone and Joint Health, University of Calgary, 3280 Hospital Drive, N.W., Calgary, AB, T2N 4Z6, Canada.
Tomasz BugajskiBiomedical Engineering Graduate Program, Schulich School of Engineering, University of Calgary, Calgary, Canada.
Sarah L ManskeBiomedical Engineering Graduate Program, Schulich School of Engineering, University of Calgary, Calgary, Canada. smanske@ucalgary.ca.
Alberta Bone and Joint Health Institute · CAUniversity of Calgary · CAUniversity of Waterloo · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe trapeziometacarpal (TMC) joint is a mechanically complex joint and is commonly affected by musculoskeletal diseases such as osteoarthritis. Quantifying in vivo TMC joint biomechanics, such as joint angles, with traditional reflective marker-based methods can be difficult due to the joint's location in the hand. Dynamic computed tomography (CT) can facilitate the quantification of TMC joint motion by continuously capturing three-dimensional volumes over time. However, post-processing of dynamic CT datasets can be time intensive and automated methods are needed to reduce processing times to allow for application to larger clinical studies. The purpose of this work is to introduce a fast, semi-automated pipeline to quantify joint angles from dynamic CT scans of the TMC joint and evaluate the associated error in joint angle and translation computation by means of a reproducibility and repeatability study.

methodsTen cadaveric hands were scanned with dynamic CT using a passive motion device to move thumbs in a radial abduction-adduction motion. Static CT scans and high-resolution peripheral quantitative CT scans were also acquired to generate high-resolution bone meshes. Abduction-adduction, flexion-extension, and axial rotation angles were computed using a joint coordinate system. Reproducibility and repeatability were assessed using intraclass correlation coefficients, Bland-Altman analysis, and root mean square errors. Target registration errors were computed to evaluate errors associated with image registration.

resultsWe found good repeatability for flexion-extension, abduction-adduction, and axial rotation angles. Reproducibility was moderate for all three angles. Joint translations exhibited greater repeatability than reproducibility. Specimens with greater joint degeneration had lower repeatability and reproducibility. We found that the difference in resulting joint angles and translations were likely due to differences in segment coordinate system definition between multiple raters, rather than due to registration errors.

conclusionsThe proposed semi-automatic processing pipeline was fast, repeatable, and moderately reproducible when quantifying TMC joint angles and translations. This work provides a range of errors for TMC joint angles from dynamic CT scans using manually selected anatomical landmarks.

Indexed as

ThumbTomography, X-Ray ComputedBiomechanical PhenomenaHumansRange of Motion, ArticularReproducibility of ResultsCadaverDynamic computed tomographyJoint angleTrapeziometacarpal joint

Identifiers

PMID36348287
PMCPMC9644596
OpenAlexW4308531407

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.