Evidence map›Paper›PMID 36347952›Full record

ArticleScientific reports2022

Test-retest reliability of splenic volume assessment by ultrasonography.

Pontus Holmström, Frank Pernett, Erika Schagatay

Abstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Biomarkers for gene therapy clinical trials of lysosomal storage disorders.Molecular therapy : the journal of the American Society of Gene Therapy · 2024
    Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Pontus HolmströmEnvironmental Physiology Group, Department of Health Sciences, Mid Sweden University, Kunskapsgatan 4, 83140, Östersund, Sweden. Pontus.holmstrom@miun.se.ORCID 0000-0003-1957-1527
Frank PernettEnvironmental Physiology Group, Department of Health Sciences, Mid Sweden University, Kunskapsgatan 4, 83140, Östersund, Sweden.ORCID 0000-0002-9787-6660
Erika SchagatayEnvironmental Physiology Group, Department of Health Sciences, Mid Sweden University, Kunskapsgatan 4, 83140, Östersund, Sweden.ORCID 0000-0001-5477-9265

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

While MRI and CT are the gold standards for assessments of splenic size in clinical settings, ultrasonography is particularly suited due to its portability, cost efficiency and easy utilization. However, ultrasonography is associated with subjective assessment, potentially resulting in increased variation. We used a test-retest design aiming to determine the reliability of splenic measurements assessed by ultrasonography during apnea. In addition, we compared reliability between different equations for volume calculations: Koga, Prolate ellipsoid and Pilström. Twelve healthy participants (6 women) performed two tests separated by 15 min, comprising a maximal voluntary apnea in a seated position. Splenic dimensions were measured via ultrasonography for 5 min before and immediately following apnea. Resting splenic volume displayed high test-retest reliability between tests (Pilström: 157 ± 39 mL vs 156 ± 34 mL, p = .651, ICC = .970, p < .001, CV = 2.98 ± 0.1%; Prolate ellipsoid: 154 ± 37 mL vs 144 ± 43 mL, p = .122, ICC = .942, p < .001, CV = 5.47 ± 0.3%; Koga: 142 ± 37 mL vs 140 ± 59 mL, p = .845, ICC = .859, p < .001, CV = 9.72 ± 1.4%). Apnea-induced volumes displayed similar reliability (127 ± 29 mL vs 129 ± 28 mL, p = .359, ICC = .967, p < .001, CV = 3.14 ± 3.1%). Reliability was also high between equations (Pilström vs Prolate ellipsoid: ICC = .818, p < .001, CV = 7.33 ± 0.3%, bias =  - 3.1 mL, LoA =  - 46.9 to 40.7 mL; Pilström vs Koga: ICC = .618, p < .01, CV = 11.83 ± 1.1%, bias =  - 14.8 mL, LoA =  - 76.9 to 47.3 mL). We conclude that splenic ultrasonographic measurements have practical applications during laboratory and field-based research as a reliable method detecting splenic volume change consistently between repeated tests. The Pilström equation displayed similar reliability compared to the prolate ellipsoid formula and slightly higher compared to the Koga formula and may be particularly useful to account for individual differences in splenic dimensions.

Indexed as

ApneaPhosmetFemaleHumansReproducibility of ResultsSpleenUltrasonographyPhosmet

Identifiers

PMID36347952
PMCPMC9643442

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.