Evidence map›Paper›PMID 36347050›Full record

ArticleJournal of applied clinical medical physics2023

Evaluation of MRI-only based online adaptive radiotherapy of abdominal region on MR-linac.

Katri Nousiainen, Grichar Valdes Santurio, Nils Lundahl, Rickard Cronholm, Carl Siversson, Jens M Edmund

Open access · goldFull text read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
4.5field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 18 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 3 countries.

Katri NousiainenDepartment of Physics, University of Helsinki, Helsinki, Finland.
Grichar Valdes SanturioDepartment of Oncology, Radiotherapy Research Unit, Herlev and Gentofte Hospital, Copenhagen University, Herlev, Denmark.
Nils LundahlSpectronic Medical AB, Helsingborg, Sweden.
Rickard CronholmSpectronic Medical AB, Helsingborg, Sweden.
Carl SiverssonSpectronic Medical AB, Helsingborg, Sweden.
Jens M EdmundDepartment of Oncology, Radiotherapy Research Unit, Herlev and Gentofte Hospital, Copenhagen University, Herlev, Denmark.
Spectronic (Sweden) · SEDanish National Institute of Public Health · DKHerlev Hospital · DKUniversity of Helsinki · FI

Funding

Doctoral Program in Materials Research and Nanoscience (MATRENA) of the University of Helsinki
6 · The paper itself

Abstract

purposeA hybrid magnetic resonance linear accelerator (MRL) can perform magnetic resonance imaging (MRI) with high soft-tissue contrast to be used for online adaptive radiotherapy (oART). To obtain electron densities needed for the oART dose calculation, a computed tomography (CT) is often deformably registered to MRI. Our aim was to evaluate an MRI-only based synthetic CT (sCT) generation as an alternative to the deformed CT (dCT)-based oART in the abdominal region.

methodsThe study data consisted of 57 patients who were treated on a 0.35 T MRL system mainly for abdominal tumors. Simulation MRI-CT pairs of 43 patients were used for training and validation of a prototype convolutional neural network sCT-generation algorithm, based on HighRes3DNet, for the abdominal region. For remaining test patients, sCT images were produced from simulation MRIs and daily MRIs. The dCT-based plans were re-calculated on sCT with identical calculation parameters. The sCT and dCT were compared in terms of geometric agreement and calculated dose.

resultsThe mean and one standard deviation of the geometric agreement metrics over dCT-sCT-pairs were: mean error of 8 ± 10 HU, mean absolute error of 49 ± 10 HU, and Dice similarity coefficient of 55 ± 12%, 60 ± 5%, and 82 ± 15% for bone, fat, and lung tissues, respectively. The dose differences between the sCT and dCT-based dose for planning target volumes were 0.5 ± 0.9%, 0.6 ± 0.8%, and 0.5 ± 0.8% at D

conclusionsThe geometric agreement metrics were within typically reported values and most average relative dose differences were within 1%. Thus, an MRI-only sCT-based approach is a promising alternative to the current clinical practice of the abdominal oART on MRL.

Indexed as

Radiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedAlgorithmsHumansMagnetic Resonance ImagingNeural Networks, ComputerRadiotherapy DosageMRI-onlyMR-linaconline adaptive radiotherapysynthetic CT

Identifiers

PMID36347050
PMCPMC10018672
OpenAlexW4308540844

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read106
Read underepoch 390

Registered trials

None linked