Evidence map›Paper›PMID 36345748›Full record

ArticleJournal of synchrotron radiation2022

X-ray diffraction with micrometre spatial resolution for highly absorbing samples.

Prerana Chakrabarti, Anna Wildeis, Markus Hartmann, Robert Brandt, Ralph Döhrmann, Giovanni Fevola, Christina Ossig, Michael Elias Stuckelberger, Jan Garrevoet, Ken Vidar Falch and 3 more

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Prerana ChakrabartiPhysics Department, University of Siegen, 57072 Siegen, Germany.
Anna WildeisMechanical Engineering Department, University of Siegen, 57076 Siegen, Germany.
Markus HartmannMechanical Engineering Department, University of Siegen, 57076 Siegen, Germany.
Robert BrandtMechanical Engineering Department, University of Siegen, 57076 Siegen, Germany.ORCID 0000-0001-7775-9662
Ralph DöhrmannCenter for X-ray and Nano Science CXNS, Deutsches Elektronen-Synchrotron DESY, 22607 Hamburg, Germany.
Giovanni FevolaCenter for X-ray and Nano Science CXNS, Deutsches Elektronen-Synchrotron DESY, 22607 Hamburg, Germany.ORCID 0000-0003-1500-0831
Christina OssigCenter for X-ray and Nano Science CXNS, Deutsches Elektronen-Synchrotron DESY, 22607 Hamburg, Germany.
Michael Elias StuckelbergerCenter for X-ray and Nano Science CXNS, Deutsches Elektronen-Synchrotron DESY, 22607 Hamburg, Germany.ORCID 0000-0002-8244-5235
Jan GarrevoetDeutsches Elektronen-Synchrotron DESY, 22607 Hamburg, Germany.ORCID 0000-0001-8696-0499
Ken Vidar FalchDeutsches Elektronen-Synchrotron DESY, 22607 Hamburg, Germany.
Vanessa GalbierzDeutsches Elektronen-Synchrotron DESY, 22607 Hamburg, Germany.
Gerald FalkenbergDeutsches Elektronen-Synchrotron DESY, 22607 Hamburg, Germany.ORCID 0000-0002-2229-1027
Peter ModreggerPhysics Department, University of Siegen, 57072 Siegen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

X-ray diffraction with high spatial resolution is commonly used to characterize (poly)crystalline samples with, for example, respect to local strain, residual stress, grain boundaries and texture. However, the investigation of highly absorbing samples or the simultaneous assessment of high-Z materials by X-ray fluorescence have been limited due to the utilization of low photon energies. Here, a goniometer-based setup implemented at the P06 beamline of PETRA III that allows for micrometre spatial resolution with a photon energy of 35 keV and above is reported. A highly focused beam was achieved by using compound refractive lenses, and high-precision sample manipulation was enabled by a goniometer that allows up to 5D scans (three rotations and two translations). As experimental examples, the determination of local strain variations in martensitic steel samples with micrometre spatial resolution, as well as the simultaneous elemental distribution for high-Z materials in a thin-film solar cell, are demonstrated. The proposed approach allows users from the materials-science community to determine micro-structural properties even in highly absorbing samples.

Indexed as

goniometershigh photon energyhigh spatial resolutionX-ray diffractionX-ray fluorescence

Identifiers

PMID36345748
PMCPMC9641556

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.