Evidence map›Paper›PMID 36345212›Full record

ArticleJournal of applied clinical medical physics2022

Digital radiography image quality evaluation using various phantoms and software.

Ioannis A Tsalafoutas, Shady AlKhazzam, Virginia Tsapaki, Huda AlNaemi, Mohammed Hassan Kharita

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ioannis A TsalafoutasMedical Physics Section, OHS Department, Hamad Medical Corporation, Doha, Qatar.
Shady AlKhazzamMedical Physics Section, OHS Department, Hamad Medical Corporation, Doha, Qatar.
Virginia TsapakiNAHU-Dosimetry and Medical Radiation Physics Section, IAEA, Vienna, Austria.
Huda AlNaemiMedical Physics Section, OHS Department, Hamad Medical Corporation, Doha, Qatar.
Mohammed Hassan KharitaMedical Physics Section, OHS Department, Hamad Medical Corporation, Doha, Qatar.

Funding

International Atomic Energy Agency (IAEA)the Qatar National Library
6 · The paper itself

Abstract

purposeTo investigate the effect of the exposure parameters on image quality (IQ) metrics of phantom images, obtained automatically using software or from visual evaluation.

methodsThree commercial phantoms and a homemade phantom constructed according to the instructions given in the IAEA Human Health Series No. 39 publication were used, along with the respective software that estimate automatically various IQ metrics. Images with various exposure parameters were acquired in a digital radiography (DR) unit. For the commercial phantoms, visual evaluations were also performed. The IQ scores obtained were analyzed to investigate the effects of increasing incident air kerma (IAK), tube potential (kVp), additional filtration, and acquisition protocol on IQ.

resultsThe effects of the exposure parameters on the IQ metrics, determined with the commercial and the IAEA phantoms, were not the same. For example, clear trends of improvement of IQ scores with increased IAK and reduction of most IQ scores with increased kVp were observed mostly with the IAEA phantom, but not with the commercial phantoms (for both automatic and visual scoring methods). For all phantoms, the maximum variations in IQ scores observed for repeated identical exposures were almost always below 10% with automatic evaluation whereas, for visual evaluation, reached 17%.

conclusionsFailure to detect some expected trends with the complex commercial phantoms may be attributed to the fact that IQ in DR is more strongly affected by the post-processing procedures, which may mask the effect of other parameters on IQ, something that was not observed with the simple IAEA phantom.

Indexed as

Radiographic Image EnhancementSoftwareHumansPhantoms, ImagingRadiation Dosagedetectabilitydigital radiographyimage qualityMTFQC phantomsSDNRSNR

Identifiers

PMID36345212
PMCPMC9797175

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked