Evidence map›Paper›PMID 36345186›Full record

ArticleJoint diseases and related surgery2022

Comparison of the radiological parameters between dynamic-referencing tactile guidance robotic system and Microplasty® instrumentation in unicompartmental knee arthroplasty.

Haluk Çabuk, Kaya Turan, Osman Görkem Muratoğlu, Tuğrul Ergün, Çağatay Öztürk, Ramazan Erden Ertürer

Abstract read
In one paragraph

Article in Joint diseases and related surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Article
  5. Article
  6. Total versus unicompartmental knee arthroplasty.Joint diseases and related surgery · 2023
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Haluk Çabuk
Kaya Turan
Osman Görkem Muratoğluİstinye Üniversitesi Tıp Fakültesi, Ortopedi ve Travmatoloji Anabilim Dalı, 34010 Zeytinburnu, İstanbul, Türkiye. osman.muratoglu@istinye.edu.tr.
Tuğrul Ergün
Çağatay Öztürk
Ramazan Erden Ertürer

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThis study aims to compare the radiological outcomes of unicompartmental knee arthroplasty (UKA) performed by a navigation-based robotic system versus Microplasty® instrumentation. PATIENTS AND

methodsBetween January 2018 and January 2019, a total of 90 knees of 75 patients (65 males, 10 females; mean age: 62.0±9.4 years; range, 50 to 73 years) were included. Among these, 54 knees underwent Oxford mobile-bearing UKA with an Microplasty® instrumentation set and 36 knees were operated with the aid of a Restoris® MCK with MAKO navigation-based robotic system. Postoperative anteroposterior and lateral X-rays of all patients were evaluated according to nine different parameters. On the femoral side, femoral varus-valgus angle, flexion-extension angle, femoral condyle posterior fit; on tibial side, tibial component varus/valgus, tibial posterior slope, medial, anterior, posterior and lateral fit of tibial component assessed.

resultsThere was no significant difference between groups in terms of age, sex, and affected side. On the femoral side, no significant difference was observed in the component position between groups. On the tibial side, tibial component medial fit (p=0.032) and anterior fit (p=0.007) were better in navigation-based robotic system group.

conclusionMicroplasty® instrumentation may lead to comparable implant positioning compared to a tactile-based navigated robotic instrumentation.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisRobotic Surgical ProceduresAgedFemaleHumansKnee JointMaleMiddle AgedTibia

Identifiers

PMID36345186
PMCPMC9647677

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.