ArticleFrontiers in digital health2022
Considerations in the reliability and fairness audits of predictive models for advance care planning.
Article in Frontiers in digital health, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
19 citing papers in PubMed.
- Navigating Healthcare AI Governance: the Comprehensive Algorithmic Oversight and Stewardship Framework for Risk and Equity.Health care analysis : HCA : journal of health philosophy and policy · 2026Article
- Review
- Bias and Fairness Across the Healthcare AI Lifecycle: A Clinician-Oriented Review.Balkan medical journal · 2026Review
- Advance Care Planning in Patients Nearing the End of Life: A Pre-intervention Study of Racial Disparities and Provider Factors.Journal of general internal medicine · 2026Article
- Artificial Intelligence in Peripheral Artery Disease: A Science Advisory From the American Heart Association.Circulation. Population health and outcomes · 2026Review
- Artificial intelligence reshaping the paradigm of hematologic malignancy diagnosis and treatment: From static assessment to dynamic precision management.Annals of hematology · 2026Review
- Artificial intelligence for colposcopic and cytological image analysis in early cervical cancer detection.iScience · 2026Review
- From model failure to system harm: operationalizing a sociotechnical pathway for healthcare AI safety.Frontiers in artificial intelligence · 2026Article
- Development of a Mortality Prediction Model for Incarcerated Adults to Identify Palliative Care Needs.Journal of general internal medicine · 2025Article
- External validation of a proprietary risk model for 1-year mortality in community-dwelling adults aged 65 years or older.Journal of the American Medical Informatics Association : JAMIA · 2025Article
- Managing risk and resilience in autonomous and intelligent systems: Exploring safety in the development, deployment, and use of artificial intelligence in healthcare.Risk analysis : an official publication of the Society for Risk Analysis · 2025Article
- The promises and limitations of artificial intelligence for quality improvement, patient safety, and research in hospital medicine.Journal of hospital medicine · 2025Article
- Value of diversity characteristics in predictive modeling: ACS screening as a case study.NPJ cardiovascular health · 2025Article
- Article
- Approaches to identify scenarios for data science implementations within healthcare settings: recommendations based on experiences at multiple academic institutions.Frontiers in digital health · 2025Article
- Developing a Research Center for Artificial Intelligence in Medicine.Mayo Clinic proceedings. Digital health · 2024Article
- Mitigating Algorithmic Bias in AI-Driven Cardiovascular Imaging for Fairer Diagnostics.Diagnostics (Basel, Switzerland) · 2024Article
- Stronger regulation of AI in biomedicine.Science translational medicine · 2023Review
- DEPLOYR: a technical framework for deploying custom real-time machine learning models into the electronic medical record.Journal of the American Medical Informatics Association : JAMIA · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
27 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Multiple reporting guidelines for artificial intelligence (AI) models in healthcare recommend that models be audited for reliability and fairness. However, there is a gap of operational guidance for performing reliability and fairness audits in practice. Following guideline recommendations, we conducted a reliability audit of two models based on model performance and calibration as well as a fairness audit based on summary statistics, subgroup performance and subgroup calibration. We assessed the Epic End-of-Life (EOL) Index model and an internally developed Stanford Hospital Medicine (HM) Advance Care Planning (ACP) model in 3 practice settings: Primary Care, Inpatient Oncology and Hospital Medicine, using clinicians' answers to the surprise question ("Would you be surprised if [patient X] passed away in [Y years]?") as a surrogate outcome. For performance, the models had positive predictive value (PPV) at or above 0.76 in all settings. In Hospital Medicine and Inpatient Oncology, the Stanford HM ACP model had higher sensitivity (0.69, 0.89 respectively) than the EOL model (0.20, 0.27), and better calibration (O/E 1.5, 1.7) than the EOL model (O/E 2.5, 3.0). The Epic EOL model flagged fewer patients (11%, 21% respectively) than the Stanford HM ACP model (38%, 75%). There were no differences in performance and calibration by sex. Both models had lower sensitivity in Hispanic/Latino male patients with Race listed as "Other." 10 clinicians were surveyed after a presentation summarizing the audit. 10/10 reported that summary statistics, overall performance, and subgroup performance would affect their decision to use the model to guide care; 9/10 said the same for overall and subgroup calibration. The most commonly identified barriers for routinely conducting such reliability and fairness audits were poor demographic data quality and lack of data access. This audit required 115 person-hours across 8-10 months. Our recommendations for performing reliability and fairness audits include verifying data validity, analyzing model performance on intersectional subgroups, and collecting clinician-patient linkages as necessary for label generation by clinicians. Those responsible for AI models should require such audits before model deployment and mediate between model auditors and impacted stakeholders.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.