Evidence map›Paper›PMID 36337187›Full record

ArticleFrontiers in veterinary science2022

Accuracy of end-on fluoroscopy in predicting implant position in relation to the vertebral canal in dogs.

Laura M Goffart, Christina Precht, Geoffrey T Fosgate, Arianna Maiolini, Bianca F Hettlich

Open access · goldAbstract read
In one paragraph

Article in Frontiers in veterinary science, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.4field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Laura M GoffartDepartment of Clinical Veterinary Medicine, Vetsuisse Faculty, University of Bern, Bern, Switzerland.
Christina PrechtDepartment of Clinical Veterinary Medicine, Vetsuisse Faculty, University of Bern, Bern, Switzerland.
Geoffrey T FosgateDepartment of Production Animal Studies, University of Pretoria, Onderstepoort, Pretoria, South Africa.
Arianna MaioliniDepartment of Clinical Veterinary Medicine, Vetsuisse Faculty, University of Bern, Bern, Switzerland.
Bianca F HettlichDepartment of Clinical Veterinary Medicine, Vetsuisse Faculty, University of Bern, Bern, Switzerland.
University of Bern · CHOnderstepoort Veterinary Academic Hospital · ZA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To evaluate the accuracy of end-on fluoroscopy in predicting implant position in relation to the vertebral canal in the canine thoracolumbar vertebral column. Study design: Animals: Canine cadaveric thoracolumbar vertebral columns ( Methods: Smooth Steinmann pins were inserted bicortically into the thoracolumbar vertebral columns between T10 and L7 using recommended insertion angles. Penetration of the spinal canal was not strictly avoided. After pin placement, end-on fluoroscopy images were obtained of each pin. Pin position was subsequently assessed by four evaluators and determined to either being out of the vertebral canal or in, with the latter being additionally divided into partially or completely penetrating the canal. To assess potential differences in modalities, fluoroscopy images were gray-scale inverted and evaluated again later by the same four individuals. Correct identification of pin position in relationship to the vertebral canal was assessed for both fluoroscopy images. Anatomic preparation of the spines was used for verification of pin position in relation to the spinal canal. Some data from this study were compared with historical data on accuracy using orthogonal radiography and computed tomography (CT). Results: Overall sensitivity and specificity of F to detect vertebral canal penetration was 98.8 % (95% confidence interval (CI), 96.0-99.6) and 98.0% (95% CI, 77.0-99.9), respectively. For Fi, sensitivity and specificity were 97.0% (95% CI, 91.5-99.0) and 98.5% (95% CI, 81.5-99.9) respectively. F exceeded Fi for the sensitivity of detecting pin penetration into the vertebral canal ( Conclusion: End-on fluoroscopy is a highly accurate method for the assessment of pin position in relationship to the thoracolumbar spinal canal in cadaveric dogs. Clinical significance: End-on fluoroscopy, with or without inversion, is accurate in identifying vertebral canal violation by bicortically placed Steinmann pins. When CT is not available, end-on fluoroscopy might be a valuable imaging modality to determine pin position in the canine vertebral column.

Indexed as

accuracybicortical pinscanineend-onfluoroscopygray-scale inversionvertebral column

Identifiers

PMID36337187
PMCPMC9630941
OpenAlexW4306945322

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.