Evidence map›Paper›PMID 36336682›Full record

ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2022

Automatic segmentation of the great arteries for computational hemodynamic assessment.

Javier Montalt-Tordera, Endrit Pajaziti, Rod Jones, Emilie Sauvage, Rajesh Puranik, Aakansha Ajay Vir Singh, Claudio Capelli, Jennifer Steeden, Silvia Schievano, Vivek Muthurangu

Abstract read
In one paragraph

Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Javier Montalt-Tordera *UCL Institute of Cardiovascular Science, UCL, London, UK.
Endrit Pajaziti *UCL Institute of Cardiovascular Science, UCL, London, UK.
Rod JonesGreat Ormond Street Hospital, London, UK.
Emilie SauvageUCL Institute of Cardiovascular Science, UCL, London, UK.
Rajesh PuranikChildren's Hospital at Westmead, Sydney, Australia.
Aakansha Ajay Vir SinghChildren's Hospital at Westmead, Sydney, Australia.
Claudio CapelliUCL Institute of Cardiovascular Science, UCL, London, UK.
Jennifer SteedenUCL Institute of Cardiovascular Science, UCL, London, UK.
Silvia SchievanoUCL Institute of Cardiovascular Science, UCL, London, UK.
Vivek MuthuranguUCL Institute of Cardiovascular Science, UCL, London, UK. v.muthurangu@ucl.ac.uk.ORCID 0000-0002-4292-6456

Funding

British Heart Foundation NH/18/1/33511British Heart Foundation PG/17/6/32797European Research Council ERC-2017-StG-757923Medical Research Council MR/S032290/1
6 · The paper itself

Abstract

backgroundComputational fluid dynamics (CFD) is increasingly used for the assessment of blood flow conditions in patients with congenital heart disease (CHD). This requires patient-specific anatomy, typically obtained from segmented 3D cardiovascular magnetic resonance (CMR) images. However, segmentation is time-consuming and requires expert input. This study aims to develop and validate a machine learning (ML) method for segmentation of the aorta and pulmonary arteries for CFD studies.

methods90 CHD patients were retrospectively selected for this study. 3D CMR images were manually segmented to obtain ground-truth (GT) background, aorta and pulmonary artery labels. These were used to train and optimize a U-Net model, using a 70-10-10 train-validation-test split. Segmentation performance was primarily evaluated using Dice score. CFD simulations were set up from GT and ML segmentations using a semi-automatic meshing and simulation pipeline. Mean pressure and velocity fields across 99 planes along the vessel centrelines were extracted, and a mean average percentage error (MAPE) was calculated for each vessel pair (ML vs GT). A second observer (SO) segmented the test dataset for assessment of inter-observer variability. Friedman tests were used to compare ML vs GT, SO vs GT and ML vs SO metrics, and pressure/velocity field errors.

resultsThe network's Dice score (ML vs GT) was 0.945 (interquartile range: 0.929-0.955) for the aorta and 0.885 (0.851-0.899) for the pulmonary arteries. Differences with the inter-observer Dice score (SO vs GT) and ML vs SO Dice scores were not statistically significant for either aorta or pulmonary arteries (p = 0.741, p = 0.061). The ML vs GT MAPEs for pressure and velocity in the aorta were 10.1% (8.5-15.7%) and 4.1% (3.1-6.9%), respectively, and for the pulmonary arteries 14.6% (11.5-23.2%) and 6.3% (4.3-7.9%), respectively. Inter-observer (SO vs GT) and ML vs SO pressure and velocity MAPEs were of a similar magnitude to ML vs GT (p > 0.2).

conclusionsML can successfully segment the great vessels for CFD, with errors similar to inter-observer variability. This fast, automatic method reduces the time and effort needed for CFD analysis, making it more attractive for routine clinical use.

Indexed as

HemodynamicsMagnetic Resonance ImagingAortaHumansPredictive Value of TestsRetrospective StudiesComputational fluid dynamicsCongenital heart diseaseMachine learningMagnetic resonance imagingNeural networkSegmentation

Identifiers

PMID36336682
PMCPMC9639271

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390