ArticleBMC ophthalmology2022

The effect of implantable collamer Lens V4c on ocular biometric measurements and intraocular lens power calculation based on Pentacam-AXL and IOLMaster 500.

Di Zhang, Meng Yang, Ziyuan Liu, Hongyuan Cai, Xiaoyong Chen, Chun Zhang

Open access · goldAbstract read
In one paragraph

Article in BMC ophthalmology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.9field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Di Zhang *Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, PR China.
Meng Yang *Beijing Fenglian Jiayuelige Ophthalmic Clinic, 18 Chaoyangmenwai Street, Chaoyang District, Beijing, 100020, PR China.
Ziyuan LiuDepartment of Ophthalmology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, PR China.
Hongyuan CaiDepartment of Ophthalmology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, PR China.
Xiaoyong ChenDepartment of Ophthalmology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, PR China. drchxy@126.com.
Chun ZhangDepartment of Ophthalmology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, PR China.
Peking University · CNBeijing Chaoyang Emergency Medical Center · CNPeking University Third Hospital · CN

Funding

Beijing Haidian Innovation and Transformation Project HDCXZHKC2021212
6 · The paper itself

Abstract

backgroundTo investigate the possible effect of implantable collamer lens (ICL) V4c on ocular biometric measurements by a new biometer Pentacam-AXL and partial coherence interferometry (PCI)-based IOLMaster 500 and intraocular lens power calculation using fourth-generation formula.

methodsWe retrospectively enrolled patients who underwent ICL (EVO-V4c, STAAR Surgical Co. Nidau, Switzerland) implantation surgery from September 2020 to November 2021. The Pentacam-AXL and IOLMaster 500 biometers were used to measure axial length (AL), anterior chamber depth (ACD), keratometry (K), white to white (WTW), and central corneal thickness (CCT) values before and at least 2 months after ICL V4c implantation. The IOL power was calculated using the Barrett Universal II formula.

resultsThe study included 45 eyes in 28 patients. There was a significant increase in ALs (average 0.03 ± 0.07 mm, p = 0.01) and a significant decrease of ACDs (average 0.19 ± 0.17 mm, p < 0.001) based on Pentacam-AXL. Similar changes in ALs and ACDs were also found in IOLMaster 500. In addition, the difference in WTWs in the two devices and that of CCTs in Pentacam-AXL were statistically significant. However, the preoperative and postoperative K1 and K2 were separately comparable using either device. The IOL power calculated by the Barrett Universal II formula did not change significantly either by the software built in Pentacam-AXL or by manually putting the parameters of the IOLMaster 500 into the formula manually (p = 0.058, p = 0.675, respectively).

conclusionsOcular parameters including ALs, ACDs, WTWs, and CCTs using a new Pentacam-AXL and standard PCI-based IOLMaster 500 changed significantly before and after the ICL V4c implantation, while IOL power prediction using the Barrett Universal II formula was little affected.

Indexed as

Lenses, IntraocularRefraction, OcularAxial Length, EyeBiometryCataractGenetic Diseases, X-LinkedHumansMicrophthalmosRetrospective StudiesBarrett universal II formulaBiometerICLIntraocular lens power

Identifiers

PMID36335303
PMCPMC9637308
OpenAlexW4308303658

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.