Evidence map›Paper›PMID 36331796›Full record

ArticleInternational journal of computer assisted radiology and surgery2023

Robotic pullback technique of a precurved cochlear-implant electrode array using real-time impedance sensing feedback.

Katherine E Riojas, Trevor L Bruns, Josephine Granna, Robert J Webster, Robert F Labadie

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.4field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Katherine E RiojasDepartment of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA. ktriojas@gmail.com.ORCID http://orcid.org/0000-0002-1845-6634
Trevor L BrunsDepartment of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA.
Josephine GrannaDepartment of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA.
Robert J WebsterDepartment of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA.
Robert F LabadieDepartment of Otolaryngology, Medical University of South Carolina, Charleston, SC, USA.
Vanderbilt University · USMedical University of South Carolina · US

Funding

National Science Foundation DGE-1445197/1937963
6 · The paper itself

Abstract

purposeDuring traditional insertion of cochlear implant (CI) electrode arrays (EAs), surgeons rely on limited tactile feedback and visualization of the EA entering the cochlea to control the insertion. One insertion approach for precurved EAs involves slightly overinserting the EA and then retracting it slightly to achieve closer hugging of the modiolus. In this work, we investigate whether electrical impedance sensing could be a valuable real-time feedback tool to advise this pullback technique.

methodsUsing a to-scale 3D-printed scala tympani model, a robotic insertion tool, and a custom impedance sensing system, we performed experiments to assess the bipolar insertion impedance profiles for a cochlear CI532/632 precurved EA. Four pairs of contacts from the 22 electrode contacts were chosen based on preliminary testing and monitored in real time to halt the robotic insertion once the closest modiolar position had been achieved but prior to when the angular insertion depth (AID) would be reduced.

resultsIn this setting, the open-loop robotic insertion impedance profiles were very consistent between trials. The exit of each contact from the external stylet of this EA was clearly discernible on the impedance profile. In closed-loop experiments using the pullback technique, the average distance from the electrode contacts to the modiolus was reduced without greatly affecting the AID by using impedance feedback in real time to determine when to stop EA retraction.

conclusionImpedance sensing, and specifically the access resistance component of impedance, could be a valuable real-time feedback tool in the operating room during CI EA insertion. Future work should more thoroughly analyze the effects of more realistic operating room conditions and inter-patient variability on this technique.

Indexed as

Cochlear ImplantationCochlear ImplantsRobotic Surgical ProceduresCochleaElectric ImpedanceElectrodes, ImplantedFeedbackHumansCochlear implantsImpedance sensingOtologyRobotic surgery

Identifiers

PMID36331796
OpenAlexW4308182083

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.