Evidence map›Paper›PMID 36331629›Full record

ArticleOral and maxillofacial surgery2024

Cost minimization analysis of indication-specific osteosynthesis material in oral and maxillofacial surgery.

Adrian Franke, Bernhard Weiland, Michaela Bučkova, Christian Bräuer, Günter Lauer, Henry Leonhardt

Open access · hybridAbstract read
In one paragraph

Article in Oral and maxillofacial surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 74% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Adrian FrankeDepartment of Oral and Maxillofacial Surgery, University Hospital Carl Gustav Carus, 01304, Dresden, Germany. adrian.franke@uniklinikum-dresden.de.ORCID http://orcid.org/0000-0001-9324-9574
Bernhard WeilandDepartment of Oral and Maxillofacial Surgery, University Hospital Carl Gustav Carus, 01304, Dresden, Germany.
Michaela BučkovaDepartment of Oral and Maxillofacial Surgery, University Hospital Carl Gustav Carus, 01304, Dresden, Germany.
Christian BräuerDepartment of Oral and Maxillofacial Surgery, University Hospital Carl Gustav Carus, 01304, Dresden, Germany.
Günter LauerDepartment of Oral and Maxillofacial Surgery, University Hospital Carl Gustav Carus, 01304, Dresden, Germany.
Henry LeonhardtDepartment of Oral and Maxillofacial Surgery, University Hospital Carl Gustav Carus, 01304, Dresden, Germany.
University Hospital Carl Gustav Carus · DEKlinik und Poliklinik für Mund-, Kiefer- und Gesichtschirurgie · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeFollowing the introduction of the Regulation (EU) 2017/745 by the European Parliament, any bioactive substance or surgical implant introduced into the human body must be documented. The regulation requires any implant to be traced back to the manufacturer. Lot numbers need to be available for every single medical implant. Also, the manufacturer is required by law to provide implants individually packaged and sterilized. Previously, model tray systems (MOS tray) were used for osteosynthesis in oral and maxillofacial surgery, in which the individual implants could not be registered separately. The new regulation made it impossible to use such processes during surgery anymore and a need for a change in the medical practice surged. We examined a possible solution for the new legislation. The aim of this prospective cohort study is to analyze the MOS tray systems to osteosynthesis materials prepackaged in sets. We record and evaluate parameters such as surgical time and documentation time. We perform a short cost analysis of our clinic. The primary aim is to determine how much time is gained or lost by the mandatory increased patient safety. The secondary aim is to describe change in costs.

methodsPatients that underwent standard surgical procedures in the clinic of oral and maxillofacial surgery of the faculty hospital Carl Gustav Carus in Dresden were included. We chose open reduction and internal fixation (ORIF) of anterior mandibular corpus fractures as well as mandibular advancement by means of bilateral sagittal split osteotomies (BSSO) as standardized procedures. Both of these procedures require two osteosynthesis plates and at least four screws for each plate. MOS trays were compared to prepackaged sterilized sets. The sets include a drill bit, two plates, and eight 5-mm screws. A total number of 40 patients were examined. We allocated 20 patients to the ORIF group and the other 20 patients to the BSSO group. Each group was evenly subdivided into a MOS tray group and a prepackaged group. Parameters such as the incision-suture time (IST) as well as the documentation time (DT) by the operating room (OR) staff to complete documentation for the implants are the main focus of investigation.

resultsFor open reduction, the incision-suture time was significantly different in favor of the MOS tray (p < 0.05). There was no difference in the BSSO groups. However, we observed a significantly different (p < 0.01) documentation time advantage for the prepackaged sets in both the ORIF and BSSO groups. On top of that, we find that by using the prepackaged kits, we are able to reduce sterilization costs by €11.53 per size-reduced container. Also, there is also a total cut of costs of €38.90 and €43.70, respectively, per standardized procedure for implant material.

conclusionsBy law, a change in the method of approaching surgery is necessary. For standardized procedures, the right choice of implants can lead to a reduction of documentation time and costs for implant material, sterilization, as well as utilizing less instruments. This in turn leads to lower costs for perioperative processing as well as provision of state-of-the-art implant quality implementing higher patient security.

Indexed as

Mandibular FracturesSurgery, OralCosts and Cost AnalysisFracture Fixation, InternalHumansOpen Fracture ReductionProspective StudiesCostsDocumentation timeEU regulationMaxillofacial surgeryPrepackagedTime

Identifiers

PMID36331629
PMCPMC10914910
OpenAlexW4308182916

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.