Evidence map›Paper›PMID 36330311›Full record

ReviewAcute medicine & surgery

Preliminary study of prehospital use of smart glasses.

Kouhei Ishikawa, Youichi Yanagawa, Soichiro Ota, Ken-Ichi Muramatsu, Hiroki Nagasawa, Kei Jitsuiki, Hiromichi Ohsaka, Tamaki Nara, Yuji Nishizaki, Hiroyuki Daida

Abstract readReview
In one paragraph

Review in Acute medicine & surgery. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Kouhei IshikawaDepartment of Acute Critical Care Medicine, Shizuoka Hospital Juntendo University Izunokuni Japan.ORCID https://orcid.org/0000-0001-7911-4825
Youichi YanagawaDepartment of Acute Critical Care Medicine, Shizuoka Hospital Juntendo University Izunokuni Japan.ORCID https://orcid.org/0000-0002-4270-6402
Soichiro OtaDepartment of Acute Critical Care Medicine, Shizuoka Hospital Juntendo University Izunokuni Japan.ORCID https://orcid.org/0000-0003-0626-9548
Ken-Ichi MuramatsuDepartment of Acute Critical Care Medicine, Shizuoka Hospital Juntendo University Izunokuni Japan.
Hiroki NagasawaDepartment of Acute Critical Care Medicine, Shizuoka Hospital Juntendo University Izunokuni Japan.ORCID https://orcid.org/0000-0001-7825-4244
Kei JitsuikiDepartment of Acute Critical Care Medicine, Shizuoka Hospital Juntendo University Izunokuni Japan.ORCID https://orcid.org/0000-0001-6700-2893
Hiromichi OhsakaDepartment of Acute Critical Care Medicine, Shizuoka Hospital Juntendo University Izunokuni Japan.ORCID https://orcid.org/0000-0002-0528-2743
Tamaki NaraMedical Technology Innovation Center Juntendo University Izunokuni Japan.
Yuji NishizakiMedical Technology Innovation Center Juntendo University Izunokuni Japan.
Hiroyuki DaidaFaculty of Health Science Juntendo University Izunokuni Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: A smart glasses system is a computerized communicator with a transparent screen and video camera that can be worn as a pair of glasses. There have been no reports on the use of smart glasses in the prehospital setting. Purpose: To conduct a preliminary investigation on whether smart glasses were smoothly used bidirectionally between the prehospital setting and the receiving hospital. Methods: From March 1, 2022, to March 31, 2022, one smart glasses unit was installed in an ambulance at one branch of the fire department near our hospital. The physician on the computer, who received video and voice transmission from the smart glasses when the ambulance was dispatched, evaluated the transmission status with regard to video reception, voice reception, and voice transmission. In addition, the activity time was compared between cases in which the smart glasses system was used (patient) and not used (control). Results: During the investigating period, 12 cases were analyzed as patients. The rate of good video reception was 75%, the rate of good voice reception was 50%, and the rate of good voice transmission was 25%. There was no significant change in the activity time between the patient and control groups. Conclusion: We performed a preliminary investigation on the usability of smart glasses in the prehospital setting. Using smart glasses, patient information was shared by video and voice before arrival at the hospital, and did not affect the activity time. However, the instability of the communication status should be recognized.

Indexed as

emergency departmentprehospitalsmart glassestrial operationusability

Identifiers

PMID36330311
PMCPMC9624074

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.