Evidence map›Paper›PMID 36329099›Full record

ArticleNPJ digital medicine2022

Abdominal aortic aneurysm monitoring via arterial waveform analysis: towards a convenient point-of-care device.

Mohammad Yavarimanesh, Hao-Min Cheng, Chen-Huan Chen, Shih-Hsien Sung, Aman Mahajan, Rabih A Chaer, Sanjeev G Shroff, Jin-Oh Hahn, Ramakrishna Mukkamala

Abstract read
In one paragraph

Article in NPJ digital medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Intrinsic PPG-ECG Coupling for Accurate and Low-Power Blood Pressure Monitoring.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  2. Feel the force: Biomechanical homeostasis of the cardiovascular system.Journal of translational internal medicine · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Mohammad Yavarimanesh *Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA.
Hao-Min Cheng *Department of Medical Education, Taipei Veterans General Hospital, Taipei, Taiwan.
Chen-Huan ChenDepartment of Medical Education, Taipei Veterans General Hospital, Taipei, Taiwan.
Shih-Hsien SungSchool of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan.
Aman MahajanDepartment of Anesthesiology and Perioperative Medicine, University of Pittsburgh, Pittsburgh, PA, USA.
Rabih A ChaerDepartment of Surgery, University of Pittsburgh, Pittsburgh, PA, USA.
Sanjeev G ShroffDepartment of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA.
Jin-Oh HahnDepartment of Mechanical Engineering, University of Maryland, College Park, MD, USA.ORCID http://orcid.org/0000-0001-5429-2836
Ramakrishna MukkamalaDepartment of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA. rmukkamala@pitt.edu.ORCID http://orcid.org/0000-0001-8918-4050

Funding

A Smartphone-Based Device for Cuff-Less and Calibration-Free Blood Pressure MonitoringR01HL146470 · NHLBI · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI MUKKAMALA, RAMAKRISHNA · 2019 to 2022
$1.1M
Towards a Convenient, Point-of-Care Device for Screening and Surveillance of Aortic AneurysmsR21EB029376 · NIBIB · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI MUKKAMALA, RAMAKRISHNA · 2021 to 2021
$410k
NHLBI NIH HHS R01 HL146470NIBIB NIH HHS R21 EB029376
6 · The paper itself

Abstract

Abdominal aortic aneurysms (AAAs) are lethal but treatable yet substantially under-diagnosed and under-monitored. Hence, new AAA monitoring devices that are convenient in use and cost are needed. Our hypothesis is that analysis of arterial waveforms, which could be obtained with such a device, can provide information about AAA size. We aim to initially test this hypothesis via tonometric waveforms. We study noninvasive carotid and femoral blood pressure (BP) waveforms and reference image-based maximal aortic diameter measurements from 50 AAA patients as well as the two noninvasive BP waveforms from these patients after endovascular repair (EVAR) and from 50 comparable control patients. We develop linear regression models for predicting the maximal aortic diameter from waveform or non-waveform features. We evaluate the models in out-of-training data in terms of predicting the maximal aortic diameter value and changes induced by EVAR. The best model includes the carotid area ratio (diastolic area divided by systolic area) and normalized carotid-femoral pulse transit time ((age·diastolic BP)/(height/PTT)) as input features with positive model coefficients. This model is explainable based on the early, negative wave reflection in AAA and the Moens-Korteweg equation for relating PTT to vessel diameter. The predicted maximal aortic diameters yield receiver operating characteristic area under the curves of 0.83 ± 0.04 in classifying AAA versus control patients and 0.72 ± 0.04 in classifying AAA patients before versus after EVAR. These results are significantly better than a baseline model excluding waveform features as input. Our findings could potentially translate to convenient devices that serve as an adjunct to imaging.

Identifiers

PMID36329099
PMCPMC9633589

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked