Evidence map›Paper›PMID 36329023›Full record

ArticleNature communications2022

Self-healable printed magnetic field sensors using alternating magnetic fields.

Rui Xu, Gilbert Santiago Cañón Bermúdez, Oleksandr V Pylypovskyi, Oleksii M Volkov, Eduardo Sergio Oliveros Mata, Yevhen Zabila, Rico Illing, Pavlo Makushko, Pavel Milkin, Leonid Ionov and 2 more

Open access · goldAbstract read
In one paragraph

Article in Nature communications, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
2.9field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 41 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Soft giant magnetoimpedance electronics enable contact-free human-machine interactions.Proceedings of the National Academy of Sciences of the United States of America · 2026
    Article
  5. Review
  6. Article
  7. Article
  8. Toward Autonomous Self-Healing in Soft Robotics: A Review and Perspective for Future Research.Advanced intelligent systems (Weinheim an der Bergstrasse, Germany) · 2025
    Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Design and Development of Transient Sensing Devices for Healthcare Applications.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 2 institutions in 2 countries.

Rui XuHelmholtz-Zentrum Dresden-Rossendorf e.V., Institute of Ion Beam Physics and Materials Research, Bautzner Landstrasse 400, 01328, Dresden, Germany. r.xu@hzdr.de.
Gilbert Santiago Cañón BermúdezHelmholtz-Zentrum Dresden-Rossendorf e.V., Institute of Ion Beam Physics and Materials Research, Bautzner Landstrasse 400, 01328, Dresden, Germany.ORCID 0000-0002-1660-4437
Oleksandr V PylypovskyiHelmholtz-Zentrum Dresden-Rossendorf e.V., Institute of Ion Beam Physics and Materials Research, Bautzner Landstrasse 400, 01328, Dresden, Germany.ORCID 0000-0002-5947-9760
Oleksii M VolkovHelmholtz-Zentrum Dresden-Rossendorf e.V., Institute of Ion Beam Physics and Materials Research, Bautzner Landstrasse 400, 01328, Dresden, Germany.ORCID 0000-0001-7246-4099
Eduardo Sergio Oliveros MataHelmholtz-Zentrum Dresden-Rossendorf e.V., Institute of Ion Beam Physics and Materials Research, Bautzner Landstrasse 400, 01328, Dresden, Germany.ORCID 0000-0002-7277-7287
Yevhen ZabilaHelmholtz-Zentrum Dresden-Rossendorf e.V., Institute of Ion Beam Physics and Materials Research, Bautzner Landstrasse 400, 01328, Dresden, Germany.
Rico IllingHelmholtz-Zentrum Dresden-Rossendorf e.V., Institute of Ion Beam Physics and Materials Research, Bautzner Landstrasse 400, 01328, Dresden, Germany.
Pavlo MakushkoHelmholtz-Zentrum Dresden-Rossendorf e.V., Institute of Ion Beam Physics and Materials Research, Bautzner Landstrasse 400, 01328, Dresden, Germany.
Pavel MilkinBavarian Polymer Institute, University of Bayreuth, Ludwig Thoma Str 36a, 95447, Bayreuth, Germany.
Leonid IonovBavarian Polymer Institute, University of Bayreuth, Ludwig Thoma Str 36a, 95447, Bayreuth, Germany.
Jürgen FassbenderHelmholtz-Zentrum Dresden-Rossendorf e.V., Institute of Ion Beam Physics and Materials Research, Bautzner Landstrasse 400, 01328, Dresden, Germany.ORCID 0000-0003-3893-9630
Denys MakarovHelmholtz-Zentrum Dresden-Rossendorf e.V., Institute of Ion Beam Physics and Materials Research, Bautzner Landstrasse 400, 01328, Dresden, Germany. d.makarov@hzdr.de.ORCID 0000-0002-7177-4308
Helmholtz-Zentrum Dresden-Rossendorf · DEBavarian Polymer Institute · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We employ alternating magnetic fields (AMF) to drive magnetic fillers actively and guide the formation and self-healing of percolation networks. Relying on AMF, we fabricate printable magnetoresistive sensors revealing an enhancement in sensitivity and figure of merit of more than one and two orders of magnitude relative to previous reports. These sensors display low noise, high resolution, and are readily processable using various printing techniques that can be applied to different substrates. The AMF-mediated self-healing has six characteristics: 100% performance recovery; repeatable healing over multiple cycles; room-temperature operation; healing in seconds; no need for manual reassembly; humidity insensitivity. It is found that the above advantages arise from the AMF-induced attraction of magnetic microparticles and the determinative oscillation that work synergistically to improve the quantity and quality of filler contacts. By virtue of these advantages, the AMF-mediated sensors are used in safety application, medical therapy, and human-machine interfaces for augmented reality.

Indexed as

Magnetic FieldsMagneticsHumans

Identifiers

PMID36329023