Evidence map›Paper›PMID 36321095›Full record

ArticleRSC advances2022

Au@bovine serum albumin nanoparticle-based acid-resistant nanozyme quartz crystal microbalance sensing of urine glucose.

Dengfeng Zhou, Wenyao Song, Shuangbin Zhang, Lan Chen, Guanglu Ge

Abstract read
In one paragraph

Article in RSC advances, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Dengfeng ZhouCAS Key Laboratory of Standardization and Measurement for Nanotechnology, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology No. 11 Zhongguancun Beiyitiao Beijing 100190 PR China chenlan@nanoctr.cn gegl@nanoctr.cn.ORCID https://orcid.org/0000-0002-9270-9580
Wenyao SongCAS Key Laboratory of Standardization and Measurement for Nanotechnology, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology No. 11 Zhongguancun Beiyitiao Beijing 100190 PR China chenlan@nanoctr.cn gegl@nanoctr.cn.
Shuangbin ZhangCAS Key Laboratory of Standardization and Measurement for Nanotechnology, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology No. 11 Zhongguancun Beiyitiao Beijing 100190 PR China chenlan@nanoctr.cn gegl@nanoctr.cn.
Lan ChenCAS Key Laboratory of Standardization and Measurement for Nanotechnology, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology No. 11 Zhongguancun Beiyitiao Beijing 100190 PR China chenlan@nanoctr.cn gegl@nanoctr.cn.ORCID https://orcid.org/0000-0002-7243-5244
Guanglu GeCAS Key Laboratory of Standardization and Measurement for Nanotechnology, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology No. 11 Zhongguancun Beiyitiao Beijing 100190 PR China chenlan@nanoctr.cn gegl@nanoctr.cn.ORCID https://orcid.org/0000-0002-2460-6686

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A robust, efficient and sensitive quartz crystal microbalance (QCM) for glucose detection has been constructed using Au@bovine serum albumin (Au@BSA) nanoparticles as an active layer. The nanoparticles serve as tandem nanozymes and their stability over natural enzymes enable the sensor to show a wider linear dynamic range between 0.05 and 15 mM, a higher acid-resistance (pH 2.0-8.0) and heat-resistance (35-60 °C) than conventional glucose oxidase (GOx)-based sensors. The sensor has been further applied to measure glucose content in artificial urine directly without dilution, where the recovery of 99.6-105.2% and the relative standard deviations (RSDs) below 0.88% confirm a good reproducibility for the measurement results. In addition, the developed Au@BSA QCM sensor can retain 95% of its initial activity after 40 days of storage. Overall, the Au@BSA sensor shows better comprehensive performance than the commercial sensor strips for urine glucose analysis and provides a promising approach in a more precise and robust manner.

Identifiers

PMID36321095
PMCPMC9575391

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.