Balloon-Expandable TAVR Bioprostheses: Area or Perimeter Sizing? A Prospective Pilot Study.

Jonathan Halim, Peter den Heijer, Jeroen Vos, Bas E Schölzel, Martijn Meuwissen, Ben van den Branden, Andreas Baumbach, Alexander J J Ijsselmuiden

Abstract read
In one paragraph

Article in Journal of interventional cardiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jonathan HalimDepartment of Cardiology, Amphia Hospital Breda, Molengracht 21, 4818 CK, Breda, Netherlands.ORCID https://orcid.org/0000-0002-4451-6848
Peter den HeijerDepartment of Cardiology, Amphia Hospital Breda, Molengracht 21, 4818 CK, Breda, Netherlands.
Jeroen VosDepartment of Cardiology, Amphia Hospital Breda, Molengracht 21, 4818 CK, Breda, Netherlands.
Bas E SchölzelDepartment of Cardiology, Amphia Hospital Breda, Molengracht 21, 4818 CK, Breda, Netherlands.
Martijn MeuwissenDepartment of Cardiology, Amphia Hospital Breda, Molengracht 21, 4818 CK, Breda, Netherlands.
Ben van den BrandenDepartment of Cardiology, Amphia Hospital Breda, Molengracht 21, 4818 CK, Breda, Netherlands.
Andreas BaumbachQueen Mary University of London, Barts Heart Centre, London, UK.
Alexander J J IjsselmuidenDepartment of Cardiology, Amphia Hospital Breda, Molengracht 21, 4818 CK, Breda, Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: In TAVR, area sizing is used for balloon-expandable (BE) valves, whereas self-expanding valves are sized to annulus perimeter. For BE valves, this seems illogical: these frames force a circular shape even on an ellipsoid annulus. This can potentially lead to relative undersizing when area sizing is being applied. We developed a perimeter-based sizing algorithm to evaluate the safety and feasibility of perimeter sizing for the Myval BE valve. Methods: In this prospective single-center study, 60 patients with severe aortic stenosis treated with the Myval BE valve were included. Perimeter sizing was used with limited oversizing of 3.7% ± 1.3% compared to the annulus perimeter. After TAVR, clinical outcomes were evaluated at 30 days and 1 year. An echocardiographic follow-up took place at 30 days. Results: At 30 days, the need for PPI and stroke occurred in 2% and 3% of the patients, respectively. Moreover, cardiac death and moderate-severe PVL were absent. At 1-year, cardiac death and stroke were observed in 3% and 8% of the patients, respectively. In 33.3% of the patients, a larger valve size was implanted compared to the valve size calculated by area sizing. Conclusions: Perimeter sizing with the Myval BE valve leads to substantial use of larger valve sizes and favorable clinical outcomes, with low PPI and the absence of significant PVL. A randomized controlled trial is being planned to prove the superiority of this alternative sizing method.

Indexed as

Aortic Valve StenosisBioprosthesisHeart Valve ProsthesisStrokeTranscatheter Aortic Valve ReplacementAortic ValveDeathHumansMultidetector Computed TomographyPilot ProjectsProspective StudiesProsthesis DesignTreatment Outcome

Identifiers

PMID36320718
PMCPMC9596236

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.