Evidence map›Paper›PMID 36318324›Full record

ArticleEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery2023

A comparative study of audiological outcomes and compliance between the Osia system and other bone conduction hearing implants.

Yehree Kim, Goun Choe, Heonjeong Oh, Byung Yoon Choi

Abstract read
PubMed Publisher
In one paragraph

Article in European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 1 pooled it
3.0field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 1 synthesis or guideline pooled it, 20 citations in OpenAlex.

  1. Guideline
  2. Patient-reported outcomes and speech-in-noise performance with OSIA versus other transcranial devices in unilateral and asymmetric hearing loss.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
    Article
  3. Review
  4. Article
  5. Clinical and surgical safety in patients transitioning from percutaneous to transcutaneous active bone conduction implants.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
    Observational
  6. Hearing Rehabilitation with OsiaYonsei medical journal · 2025
    Article
  7. Long-term clinical and audiometric outcomes after the implantation of piezoelectric bone conduction devices in children: a prospective cohort study.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2025
    Article
  8. Active piezoelectric bone conduction implant OsiaEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2025
    Article
  9. Bone-conduction Hearing Aids: A Scoping Review.Indian journal of otolaryngology and head and neck surgery : official publication of the Association of Otolaryngologists of India · 2024
    Article
  10. Article
  11. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Yehree KimDepartment of Otorhinolaryngology-Head and Neck Surgery, Seoul National University Bundang Hospital, 300 Gumi-Dong, Bundang-Gu, Seongnam, 13620, Republic of Korea.
Goun ChoeDepartment of Otorhinolaryngology-Head and Neck Surgery, Sejong Chungnam National University Hospital, Sejong, Korea.
Heonjeong OhDepartment of Otorhinolaryngology-Head and Neck Surgery, Seoul National University Bundang Hospital, 300 Gumi-Dong, Bundang-Gu, Seongnam, 13620, Republic of Korea.
Byung Yoon ChoiDepartment of Otorhinolaryngology-Head and Neck Surgery, Seoul National University Bundang Hospital, 300 Gumi-Dong, Bundang-Gu, Seongnam, 13620, Republic of Korea. choiby2010@gmail.com.ORCID http://orcid.org/0000-0001-5125-2118
Seoul National University Bundang Hospital · KRChungnam National University Hospital · KR

Funding

Ministry of Education 2021R1A2C2092038Seoul National University Bundang Hospital SNUBH- 13-2022-0010
6 · The paper itself

Abstract

purposeTo examine the subjective and objective audiological benefits of the Osia system compared to devices commonly implanted prior to the introduction of this system.

methodsOsia recipients with either conductive hearing loss (CHL/MHL) (n = 9) or single-sided deafness (SSD) (n = 8) who underwent surgery from February 2021 to March 2022 were prospectively recruited. The audiological outcomes and usage rate of Osia implantees were compared with those of retrospectively recruited patients implanted with other devices (n = 50). The subjective satisfaction of the Osia implantees was also evaluated through questionnaires.

resultsAll users of the Osia system were classified as regular users. In the CHL/MHL group, the effective gain of the Osia system (11.1 ± 14.9 dB) surpassed that of the Baha and Bonebridge (- 2.7 ± 12.6 dB) at 2 kHz (p = 0.01, Mann-Whitney U test). Among the devices, the Osia system tended to tolerate the worst bone conduction thresholds, up to the level of 61 dB. In the SSD group, the functional gain of Osia at 4 kHz (37.5 ± 3.1 dB) was higher than that of the Baha and Bonebridge group (26.9 ± 3.0 dB) (p = 0.05, Mann-Whitney U test).

conclusionThe Osia system yielded larger audiological gain than the Baha Attract and Bonebridge devices, especially at high frequencies, leading to substantially higher compliance. The Osia system tended to have the strongest tolerance to aggravated bone conduction thresholds among the available transcutaneous bone conduction hearing implants. Therefore, the Osia system could potentially be a good option for CHL/MHL patients with bone conduction thresholds of 50 dB HL or more, as well as patients with SSD.

Indexed as

Hearing AidsHearing Loss, Mixed Conductive-SensorineuralSpeech PerceptionBone ConductionHearing Loss, ConductiveHumansRetrospective StudiesTreatment OutcomeBahaBonebridgeBone conduction hearing implantsHigh frequency gainOsiaUsage rate

Identifiers

PMID36318324
OpenAlexW4307842658

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.