Evidence map›Paper›PMID 36316525›Full record

ArticleEuropean radiology experimental2022

A 72-channel receive array coil allows whole-heart cine MRI in two breath holds.

Hugo Klarenberg, Mark Gosselink, Bram F Coolen, Tim Leiner, Aart J Nederveen, Adrianus J Bakermans, Hildo J Lamb, S Matthijs Boekholdt, Martijn Froeling, Gustav J Strijkers

Open access · goldAbstract read
In one paragraph

Article in European radiology experimental, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.7field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 1 country.

Hugo KlarenbergDepartment of Biomedical Engineering and Physics, Amsterdam University Medical Centers, Amsterdam Cardiovascular Sciences, University of Amsterdam, Amsterdam, The Netherlands. h.klarenberg@amsterdamumc.nl.ORCID 0000-0002-1477-3675
Mark GosselinkDepartment of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands.
Bram F CoolenDepartment of Biomedical Engineering and Physics, Amsterdam University Medical Centers, Amsterdam Cardiovascular Sciences, University of Amsterdam, Amsterdam, The Netherlands.
Tim LeinerDepartment of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands.
Aart J NederveenDepartment of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands.
Adrianus J BakermansDepartment of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands.
Hildo J LambDepartment of Radiology, Leiden University Medical Center, Leiden, The Netherlands.
S Matthijs BoekholdtDepartment of Cardiology, Amsterdam University Medical Centers, Amsterdam Cardiovascular Sciences, University of Amsterdam, Amsterdam, The Netherlands.
Martijn FroelingDepartment of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands.
Gustav J StrijkersDepartment of Biomedical Engineering and Physics, Amsterdam University Medical Centers, Amsterdam Cardiovascular Sciences, University of Amsterdam, Amsterdam, The Netherlands.
Amsterdam University Medical Centers · NLUniversity Medical Center Utrecht · NLLeiden University Medical Center · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA new 72-channel receive array coil and sensitivity encoding, compressed (C-SENSE) and noncompressed (SENSE), were investigated to decrease the number of breath-holds (BHs) for cardiac magnetic resonance (CMR).

methodsThree-T CMRs were performed using the 72-channel coil with SENSE-2/4/6 and C-SENSE-2/4/6 accelerated short-axis cine two-dimensional balanced steady-state free precession sequences. A 16-channel coil with SENSE-2 served as reference. Ten healthy subjects were included. BH-time was kept under 15 s. Data were compared in terms of image quality, biventricular function, number of BHs, and scan times.

resultsBHs decreased from 7 with C-SENSE-2 (scan time 70 s, 2 slices/BH) to 3 with C-SENSE-4 (scan time 42 s, 4-5 slices/BH) and 2 with C-SENSE-6 (scan time 28 s, 7 slices/BH). Compared to reference, image sharpness was similar for SENSE-2/4/6, slightly inferior for C-SENSE-2/4/6. Blood-to-myocardium contrast was unaffected. C-SENSE-4/6 was given lower qualitative median scores, but images were considered diagnostically adequate to excellent, with C-SENSE-6 suboptimal. Biventricular end-diastolic (EDV), end-systolic (ESV) and stroke volumes, ejection fractions (EF), cardiac outputs, and left ventricle (LV)-mass were similar for SENSE-2/4/6 with no systematic bias and clinically appropriate limits of agreements. C-SENSE slightly underestimated LV-EDV (-6.38 ± 6.0 mL, p < 0.047), LV-ESV (-7.94 ± 6.0 mL, p < 0.030) and overestimated LV-EF (3.16 ± 3.10%; p < 0.047) with C-SENSE-4. Bland-Altman analyses revealed minor systematic biases in these variables with C-SENSE-2/4/6 and for LV-mass with C-SENSE-6.

conclusionsUsing the 72-channel coil, short-axis CMR for quantifying biventricular function was feasible in two BHs where SENSE slightly outperformed C-SENSE.

Indexed as

Breath HoldingMagnetic Resonance Imaging, CineHeart VentriclesHumansReproducibility of ResultsVentricular Function, LeftBreath holdingHealthy volunteersHeart ventriclesMagnetic resonance imaging (cine)Stroke volume

Identifiers

PMID36316525
PMCPMC9622972
OpenAlexW4307739605

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked