Evidence map›Paper›PMID 36315528›Full record

ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2022

2-D Array Design and Fabrication With Pitch-Shifting Interposer at Frequencies From 4 MHz up to 10 MHz.

Haochen Kang, Yizhe Sun, Robert Wodnicki, Qingqing He, Yushun Zeng, Gengxi Lu, Jung-Yeol Yeom, Yang Yang, Qifa Zhou

Abstract read
In one paragraph

Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. High-Frequency Wearable Ultrasound Array Belt for Small Animal Echocardiography.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2024
    Article
  4. High-Frequency, 2-mm-Diameter Forward-Viewing 2-D Array for 3-D Intracoronary Blood Flow Imaging.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2024
    Article
  5. Article
  6. Design of Preamplifier for Ultrasound Transducers.Sensors (Basel, Switzerland) · 2024
    Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Haochen Kang
Yizhe Sun
Robert Wodnicki
Qingqing He
Yushun Zeng
Gengxi Lu
Jung-Yeol Yeom
Yang Yang
Qifa Zhou

Funding

Ophthalmic Therapeutics Engineering CoreP30EY029220 · NEI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI Mahnaz Shahidi · 2018 to 2026
$6.5M
High Resolution Ultrasound in Interventional RadiologyR01CA271309 · NCI · STANFORD UNIVERSITY · PI Katherine W Ferrara, Qifa Zhou · 2022 to 2026
$3.1M
High-resolution Elastographic Assessment of the Optic Nerve HeadR01EY028662 · NEI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI CHEN, ZHONGPING, SIGAL, IAN A · 2018 to 2021
$2.7M
Biomechanical mapping of the optic nerve head and peripapillary sclera using high frequency ultrasonic elastographyR01EY032229 · NEI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI ZHOU, QIFA · 2021 to 2024
$2.6M
Non-invasive Ultrasound Stimulated Retinal ProsthesisR01EY030126 · NEI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI ZHOU, QIFA · 2019 to 2022
$2.0M
NCI NIH HHS R01 CA271309NEI NIH HHS P30 EY029220NEI NIH HHS R01 EY028662NEI NIH HHS R01 EY030126NEI NIH HHS R01 EY032229
6 · The paper itself

Abstract

High element density and strict constraints of the element's size have significantly limited the design and fabrication of 2-D ultrasonic arrays, especially fully sampled 2-D arrays. Recently, 3-D printing technology has been one of the most rapidly developing fields. Along with the great progress of 3-D printing technology, complex and detailed 3-D structures have become readily available with a short iteration cycle, which allows us to reduce the complexity of routing and helps to ameliorate assembly problems in 2-D ultrasound array fabrication. In this work, we designed and fabricated 2-D ultrasound arrays for an array of applications with a pitch-shifting interposer, which allowed us to fit different array designs with the same circuit design and significantly reduce the requirements in routing and connection for 2-D array fabrication at frequencies from 4 to 10 MHz. Results demonstrated that this design would make 2-D arrays more available and affordable.

Indexed as

TransducersUltrasonicsEquipment DesignUltrasonography

Identifiers

PMID36315528
PMCPMC10353697

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.