ArticleActa orthopaedica2022
Inducible displacement CT increases the diagnostic accuracy of aseptic loosening in primary total hip arthroplasty.
Article in Acta orthopaedica, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06924567 (The Accuracy of CT-based Implant Movement for the Evaluation of Cup and Stem Stability, When Plain Radiography is Not Conclusive for Loosening, in Patients Scheduled for Revision Hip Arthroplasty. A Multicenter Study), which is not on this map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
The Accuracy of CT-based Implant Movement for the Evaluation of Cup and Stem Stability, When Plain Radiography is Not Conclusive for Loosening, in Patients Scheduled for Revision Hip Arthroplasty. A Multicenter Study
Who cites it
9 citing papers in PubMed.
- CT Motion-Analysis of Implant Loosening in Total Wrist Arthroplasty: A Pilot Study.Journal of wrist surgery · 2026Article
- Article
- Inducible displacement CT for implant loosening detection: a scoping review on methods, validation, and challenges.Acta orthopaedica · 2026Article
- Provocation CT-Based Analysis for Diagnosis of Hip and Knee Arthroplasty Aseptic Loosening: Where Are We at? A Systematic Review of Clinical Trials.Journal of clinical medicine · 2025Review
- Evaluation of conventional and CT-based radiostereometric analysis for inducible displacement measurements after total hip arthroplasty.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2025Article
- Guideline for RSA and CT-RSA implant migration measurements: an update of standardizations and recommendations.Acta orthopaedica · 2024Article
- Load-induced deformation of the tibia and its effect on implant loosening detection.Scientific reports · 2023Article
- Cost-effectiveness of implant movement analysis in aseptic loosening after hip replacement: a health-economic model.Cost effectiveness and resource allocation : C/E · 2023Article
- Computed tomography-based radiostereometric analysis in orthopedic research: practical guidelines.Acta orthopaedica · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background and purposeInducible displacement CT compares 2 CTs acquired in series but with alternated rotation of the femur. This provides visual and quantitative clues as to the mechanical situation, i.e., loosening, of a total hip arthroplasty. We report the accuracy of this method as well as the experience of integrating it into a clinical workflow. PATIENTS AND
methodsThis was a retrospective single centre study of 72 cases of suspected aseptic loosening were the surgeon after reviewing a standard plain radiograph saw a need for more information. The displacement CT and plain radiograph were compared either to intraoperative findings or a 1-3 year follow up questionnaire for patients that did not have revision surgery. Patients reporting degradation in status since the time of the displacement CT were called for a follow up plain radiograph. Sensitivity and specificity were assessed, and user experience gathered.
resultsOf 72 enrolled patients 15 were lost to follow up. Of the remaining 57, 17 were judged by in-traoperative findings or follow-up to have had loose implants. For plain radiography the sensitivity and specificity were 59% (95% CI 35-82) and 85% (74-96). For displacement CT the corresponding values were 77% (56-97), and 100% (100-100) respectively. The tool was adaptable to clinical routine.
conclusionDisplacement CT with alternated rotations of the femur is a viable option to improve the diagnostic process for identifying aseptic loosening in a total hip arthroplasty.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.