The Reliability of Automated Three-Dimensional Echocardiography-HeartModel
Article in Medical archives (Sarajevo, Bosnia and Herzegovina), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 7 citations in OpenAlex.
- Artificial Intelligence in Cardiovascular Medicine: A Giant Step in Personalized Medicine?Journal of personalized medicine · 2026Review
- Comparing HeartModelBMC cardiovascular disorders · 2024Article
- A deep learning model for classifying left ventricular enlargement for both transthoracic echocardiograms and handheld cardiac ultrasound.European heart journal. Imaging methods and practice · 2024Article
- Acquisition of New Philips Affiniti 30 Vascular Color Doppler Ultrasound Device - Cost Benefit Analysis to Reduce Cardiosurgical Patients' Treatment.Materia socio-medica · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Two-dimensional echocardiography (2DE) Simpson methods is the most frequently used imaging modality to assess Left ventricular ejection fraction (LVEF). LVEF is an important predictor of morbidity and mortality in a wide range of patients and clinical scenarios. Despite its importance in prognosis and clinical decision making, most echocardiography laboratories currently determine EF primarily by visual estimation, which is highly experience-dependent and sensitive to intra- and inter-observer variability and suboptimal accuracy and repeatability. Over the last decade, 3-dimensional echocardiography (3DE) has become increasingly implemented in clinical practice. The automated 3D HeartModel Objective: The objective of the study was to compare the automated 3D HeartModel Methods: The study prospectively enrolled 165 patients with symptoms of LV dysfunction (ischemic or nonischemic) and New York Heart Association (NYHA) functional class I-III, referred for an echocardiographic study to evaluate the LV volumes and LV ejection fraction (LVEF) during the period from March 2020 to March 2022. Echocardiographic images were acquired by experienced echocardiographers using a commercially available Philips EPIQ machine (Koninklijke Philips Ultrasound, USA) equipped with X5-1 Matrix probe for 2DE and DHM 3DE acquisitions, respectively. Results: 2D Simpson methods echocardiography results for estimated LVEF were 38.43 ± 1.70 in patients with NYHA class I-II, 30.53 ± 1.60 in patients with NYHA class III. Using 3D Heart Model, LVEF were 38.23 ± 1.71 in patients with NYHA class I-II and 30.27 ± 1.50 in patients with NYHA class III. The results of 2D Simpson methods echocardiography for estimated LVEDVi in NYHA class I-II and NYHA class III were 99.06 ± 6.36 ml/m2, 121.96 ± 2.93 ml/m2 respectively, LVESVi were 60.91 ± 3.91 ml/m2, 84.74 ± 2.70 ml/m2 respectively, for 3D Heart Model, LVEDVi in NYHA class I-II and NYHA class III were 100.07 ± 6.72, 121.38 ± 3.01 ml/m2 respectively, LVESVi were 61.75 ± 3.94 ml/m2, 84.73 ± 2.33 ml/m2 respectively. 2DE measurement of LV volumes and EF was completed in 6.1 ± 0.8 min. per patient. 3DE HeartModel Conclusion: 3D DHM provides fast and accurate LV volumes and LVEF quantitation, as it avoids geometric assumptions and left ventricular foreshortening, has better reproducibility and has incremental value to predict adverse outcomes in comparison with conventional 2DE. In the future major benefit of AI in echocardiography is expected from improvements in automated analysis and interpretation to reduce workload and improve clinical outcome.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials