ArticleCureus2022
Three-Dimensional Analysis Versus Two-Dimensional Slice-Based Analysis of CT for Measuring Femoral Torsion and Its Correlation to Passive Hip Range of Motion.
Article in Cureus, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Computer Vision in Lower Limb Orthopaedics: A Scoping Review of Imaging-Based Artificial Intelligence Applications.Cureus · 2025Review
- Semiautomated Three-Dimensional Landmark Placement on Knee Models Is a Reliable Method to Describe Bone Shape and Alignment.Arthroscopy, sports medicine, and rehabilitation · 2025Article
- A novel plate design for rotational guided growth: An experimental study in immature porcine femurs.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2025Article
- Computed tomography-based automated 3D measurement of femoral version: Validation against standard 2D measurements in symptomatic patients.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2024Article
- A surface registration-based approach for assessment of 3D angles in guided growth interventions in the growing femur.Journal of experimental orthopaedics · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction Femoral torsion is an important anatomical consideration of the hip that has major implications on the natural motion of the hip joint. Similarly, it affects pathologic conditions of the hip, including femoroacetabular impingement, dysplasia, and/or microinstability. Femoral torsion is typically measured on two-dimensional (2D) axial CT cuts by creating the angle between the femoral neck and the posterior aspect of the ipsilateral femoral condyles. Position of the leg during imaging may affect 2D measurements. Three-dimensional (3D) analysis of a hip CT with inclusion of femoral alignment may portray the anatomy of the hip more accurately as compared to a 2D slice-based analysis of a hip CT scan. It is thought that femoral torsion measured using this system could be a more accurate and reliable means of measurement. The primary purpose of this study is to assess the differences in measuring femoral torsion with 3D modeling and analysis compared to the standard 2D slice-based approach on a CT scan. Secondarily, we attempt to determine how the passive range of motion of the hip correlates with femoral torsion measured using the 3D model versus the 2D model. Methods In a prospective cohort study of 20 patients, femoral torsion was assessed using both 2D analysis and 3D analysis. The differences between these measurements on each of the imaging modalities were compared. Additionally, each patient had the passive range of motion of their hip measured with a goniometer. The amount of internal and external rotation was measured with the hip in a neutral position and with the hip flexed to 90°. Acetabular version, combined version, and alpha angle were added to multivariate regression analysis to evaluate their effect versus femoral torsion alone. Results Femoral antetorsion measured using the standard 2D slice-based approach on CT scan was 22.1° (SD: 11.1°), which was higher (p<0.001) than that using 3D analysis (8.25°; SD: 10.5°). There was a strong correlation between femoral torsion measurements using 3D analysis and 2D analysis (R=0.91). Based on 3D analysis, there was a moderate correlation between femoral torsion and passive hip external rotation measured with the hip flexed to 90° (R=0.65, p<0.002) and with the hip in a neutral position (R=0.58, p<0.007). Conclusion There was a significant difference between femoral torsion measurements using the 3D analysis, which showed approximately 14° of less antetorsion on average. Additionally, rotation of the hip and femoral torsion was correlated to higher levels of antetorsion associated with more internal rotation of the hip.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.