Evidence map›Paper›PMID 36309361›Full record

ArticleIn vivo (Athens, Greece)

Comparison of Formation of Capsule Among Different Breast Silicone Implants.

Xin Rui Zhang, Pham Ngoc Chien, Xuan-Tung Trinh, Sun-Young Nam, Chan-Yeong Heo

Open access · diamondAbstract read
In one paragraph

Article in In vivo (Athens, Greece). The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 1 pooled it
3.7field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 1 synthesis or guideline pooled it, 17 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Article
  6. Review
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Xin Rui Zhang *Department of Plastic and Reconstructive Surgery, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.
Pham Ngoc Chien *Department of Plastic and Reconstructive Surgery, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.
Xuan-Tung Trinh *Department of Plastic and Reconstructive Surgery, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.
Sun-Young NamDepartment of Plastic and Reconstructive Surgery, Seoul National University Bundang Hospital, Seongnam, Republic of Korea; 99261@snubh.org.
Chan-Yeong HeoDepartment of Plastic and Reconstructive Surgery, Seoul National University Bundang Hospital, Seongnam, Republic of Korea; lionheo@snu.ac.kr.
Seoul National University Bundang Hospital · KRSeoul National University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND/

aimSilicone implants are widely used biomaterials in surgeries owing to their physiological inertness and low toxicity. However, capsular contracture is a severe complication caused by the insertion of breast implants, which can endanger the health of patients. In this study, twelve different silicone breast implants were tested to determine which could lead to a lower incidence of capsular contracture. MATERIALS AND

methodsFor in vivo experiments, these silicone implants were implanted into 60 rats (i.e., five implants per rat). The implants were explanted eight weeks after the operation. Samples were analyzed and measured by using hematoxylin and eosin staining, Masson's trichrome staining, and immunofluorescence staining methods. We compared twelve samples for their differences in the thickness of capsular formation, number of inflammatory cells, collagen expression, fibroblast intensity (i.e., Vimentin and α-SMA), and inflammatory cytokines (i.e., IL-8, CD68, MCP-1, and F4/80).

resultsDifferent surface textures of breast implants gave different effects on capsular thickness, collagen formation, fibroblast formation, and potential inflammation. Samples that had smooth textures such as SEBBIN, HANS, and Mentor showed higher collagen formation than other samples. SEBBIN Texture, Motiva Micro, HANS Smooth I, and HANS Micro exhibited higher fibroblast formation (i.e., α-SMA, Vimentin). SEBBIN Smooth and samples in HANS group displayed lower expression of inflammation cytokines (IL-8, CD68, MCP-1, and F4/80).

conclusionThese findings provide preliminary reports on the surface texture effect and support a selection of breast silicone implants in breast reconstruction to avoid the formation of capsular contracture after implantation.

Indexed as

Breast ImplantationBreast ImplantsContractureAnimalsCollagenInflammationInterleukin-8RatsSilicone GelsVimentinCollagenInterleukin-8Silicone GelsVimentinanaplastic large cell lymphomabacterial biofilmscapsular contractureSilicone implantssurface texture

Identifiers

PMID36309361
PMCPMC9677790
OpenAlexW4307843769

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.