ArticleGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie2023

Comparison of 2 modern swept-source optical biometers-IOLMaster 700 and Anterion.

Achim Langenbucher, Nóra Szentmáry, Alan Cayless, Jascha Wendelstein, Peter Hoffmann

Full text read
In one paragraph

Article in Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Astigmatism Management in Modern Cataract Surgery.Vision (Basel, Switzerland) · 2024
    Review
  8. Article
  9. Article
  10. Article
  11. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Achim LangenbucherDepartment of Experimental Ophthalmology, Saarland University, Kirrberger Str 100 Bldg. 22, 66424, Homburg, Saar, Germany. achim.langenbucher@uks.eu.ORCID http://orcid.org/0000-0001-9175-6177
Nóra SzentmáryDr. Rolf M. Schwiete Center for Limbal Stem Cell and Aniridia Research, Saarland University, Homburg, Saar, Germany.
Alan CaylessSchool of Physical Sciences, The Open University, Milton Keynes, UK.
Jascha WendelsteinDepartment of Ophthalmology, Johannes Kepler University, Linz, Austria.
Peter HoffmannAugen- und Laserklinik Castrop-Rauxel, Castrop-Rauxel, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare biometric measures from 2 modern swept-source OCT biometers (IOLMaster700 (Z, Carl-Zeiss-Meditec) and Anterion (H, Heidelberg Engineering)) and evaluate the effect of measurement differences on the resulting lens power (IOLP).

methodsBiometric measurements were made on a large study population with both instruments. We compared axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT) and corneal front and back surface curvature measurements. Corneal curvature was converted to power vectors and total power derived using the Gullstrand formula. A paraxial lens power calculation formula and a prediction for the IOL axial position according to the Castrop formula were used to estimate differences in IOLP targeting for emmetropia.

resultsThere were no systematic differences between measurements of AL (- 0.0146 ± 0.0286 mm) and LT (0.0383 ± 0.0595 mm), whereas CCT yielded lower (7.8 ± 6.6 µm) and ACD higher (0.1200 ± 0.0531 mm) values with H. With H, CCT was lower for thicker corneas. The mean corneal front surface radius did not differ (- 0.4 ± 41.6 µm), but the corneal back surface yielded a steeper radius (- 397.0 ± 74.6 µm) with H, giving lower mean total power (- 0.3469 ± 0.2689 dpt). The astigmatic vector components in 0°/90° and 45°/135° were the same between both instruments for the front/back surface or total power.

conclusionThe biometric measures used in standard formulae (AL, corneal front surface curvature/power) are consistent between instruments. However, modern formulae involving ACD, CCT or corneal back surface curvature may yield differences in IOLP, and therefore, formula constant optimisation customised to the biometer type is required.

Indexed as

Lens, CrystallineLenses, IntraocularAnterior ChamberAxial Length, EyeBiometryCorneaHumansReproducibility of ResultsTomography, Optical CoherenceAnterionIntraocular lens power calculationIOLMaster700Optical biometerPower vector analysisSwept-source OCT

Identifiers

PMID36307658
PMCPMC10049935

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read76
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.