ArticleAmerican journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics2022
The effects of different types of periodontal ligament material models on stresses computed using finite element models.
Article in American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 26 citations in OpenAlex.
- Biomechanical analysis of retracting maxillary incisors using clear aligners with palatal mini-implants in extraction cases: a finite-element analysis.BMC oral health · 2026Article
- Stress distribution in different tooth-implant supported mandibular prostheses rehabilitating unilateral free-end saddle: a biomechanical comparative finite element study.BMC oral health · 2026Article
- Article
- [Research progress on three-dimensional finite element analysis for fixed implant restoration of edentulous jaw].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2026Review
- Comparative effects of temporary anchorage devices combined with various auxiliary attachments on maxillary molar mesialization with clear aligners: a finite element analysis.BMC oral health · 2026Article
- Combined effects and weight analysis of factors affecting initial maxillary central incisor retraction: a three-dimensional finite element study.Frontiers in bioengineering and biotechnology · 2026Article
- Mechanical forces orchestrate the epigenetic landscape of oral mesenchymal stem/progenitor cell fate in dental and periodontal tissues.Frontiers in cell and developmental biology · 2026Review
- Correction of the curve of spee using clear aligner therapy: A finite element analysis of three lower anterior intrusion protocols.PloS one · 2026Article
- Biomechanical effect of combined use of mini-screws and aligners in preventing uncontrolled tipping of the incisor and mesial tipping of the molar: a three-dimensional finite element study.Progress in orthodontics · 2025Article
- Standing CT-based finite element models efficiently identify regions of high mechanical strain in equine metacarpal subchondral bone.Scientific reports · 2025Article
- The effects of anterior spaces on the intrusion of mandibular incisors with clear aligners in extraction cases: a finite-element analysis.BMC oral health · 2025Article
- Exploring the mechanical and biological interplay in the periodontal ligament.International journal of oral science · 2025Review
- Fracture Resistance of Provisional Crowns: A Finite Element Analysis of a Semi-Permanent Resin-A Pilot Study.Dentistry journal · 2025Article
- Comparative study of torque expression and its biomechanical effects: spherical self-ligating bracket with lock-hook system versus passive self-ligating bracket and conventional bracket.BMC oral health · 2025Article
- Automated Support Generation for Fixed Partial Dentures and Impact of Bone Loss, Bone Quality and Support Types: Parametric Cad and Finite Element Analysis.Dentistry journal · 2024Article
- A New Multi-Axial Functional Stress Analysis Assessing the Longevity of a Ti-6Al-4V Dental Implant Abutment Screw.Biomimetics (Basel, Switzerland) · 2024Article
- Influence of Connector Design on Displacement and Micromotion in Tooth-Implant Fixed Partial Dentures Using Different Lengths and Diameters: A Three-Dimensional Finite Element Study.Materials (Basel, Switzerland) · 2024Article
- The effect of enhanced structure in the posterior segment of clear aligners during anterior retraction: a three-dimensional finite element and experimental model analysis.Progress in orthodontics · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 2 countries.
Funding
Abstract
introductionFinite element (FE) method has been used to calculate stress in the periodontal ligament (PDL), which is crucial in orthodontic tooth movement. The stress depends on the PDL material property, which varies significantly in previous studies. This study aimed to determine the effects of different PDL properties on stress in PDL using FE analysis.
methodsA 3-dimensional FE model was created consisting of a maxillary canine, its surrounding PDL, and alveolar bone obtained from cone-beam computed tomography scans. One Newton of intrusion force was applied vertically to the crown. Then, the hydrostatic stress and the von Mises stress in the PDL were computed using different PDL material properties, including linear elastic, viscoelastic, hyperelastic, and fiber matrix. Young's modulus (E), used previously from 0.01 to 1000 MPa, and 3 Poisson's ratios, 0.28, 0.45, and 0.49, were simulated for the linear elastic model.
resultsThe FE analyses showed consistent patterns of stress distribution. The high stresses are mostly concentrated at the apical area, except for the linear elastic models with high E (E >15 MPa). However, the magnitude varied significantly from -14.77 to -127.58 kPa among the analyzed patients. The E-stress relationship was not linear. The Poisson's ratio did not affect the stress distribution but significantly influenced the stress value. The hydrostatic stress varied from -14.61 to -95.48 kPa.
conclusionsDifferent PDL material properties in the FE modeling of dentition do not alter the stress distributions. However, the magnitudes of the stress significantly differ among the patients with the tested material properties.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.