Evidence map›Paper›PMID 36305737›Full record

ArticleArtificial organs2023

Prevention of thrombus formation in blood pump by mechanical circular orbital excitation of impeller in magnetically levitated centrifugal pump.

Kohei Hatakenaka, Wataru Hijikata, Tatsuki Fujiwara, Katsuhiro Ohuchi, Yusuke Inoue

Open access · hybridAbstract read
In one paragraph

Article in Artificial organs, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 52% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Kohei HatakenakaSchool of Engineering, Tokyo Institute of Technology, Tokyo, Japan.
Wataru HijikataSchool of Engineering, Tokyo Institute of Technology, Tokyo, Japan.ORCID https://orcid.org/0000-0002-5433-1919
Tatsuki FujiwaraDepartment of Cardiovascular Surgery, Tokyo Medical and Dental University, Tokyo, Japan.ORCID https://orcid.org/0000-0002-6931-1152
Katsuhiro OhuchiCenter for Experimental Animals, Tokyo Medical and Dental University, Tokyo, Japan.
Yusuke InoueAdvanced Medical Engineering Research Center, Asahikawa Medical University, Asahikawa, Japan.ORCID https://orcid.org/0000-0002-1032-4207
Tokyo Institute of Technology · JPTokyo Medical and Dental University · JPAsahikawa Medical University · JP

Funding

Japan Agency for Medical Research and Development JP21he0422013Japan Society for the Promotion of Science JP20H02098
6 · The paper itself

Abstract

backgroundMechanical circulatory support devices, such as left ventricular assist devices, have recently been used in patients with heart failure as destination therapy but the formation of thrombus in blood pumps remains a critical problem. In this study, we propose a mechanical antithrombogenic method by impeller excitation using a magnetically levitated (Maglev) centrifugal pump. Previous studies have shown that one-directional excitation prevents thrombus; however, it is effective in only one direction. In this study, we aimed to obtain a better effect by vibrating it in a circular orbit to induce uniform changes in the shear-rate field entirely around the impeller.

methodsThe blood coagulation time was compared using porcine blood. (1) The flow rate was set to 1 L/min, and applied excitation was at a frequency of 280 Hz and amplitude of 3 μm. (2) Moreover, the effect was compared by varying the frequency, amplitude, and direction of the excitation. In this experiment, the flow rate was set to 0.3 L/min.

results(1) The thrombus formation time was 77 min without excitation and 133 min with excitation, which was 1.7 times longer. (2) The results showed no difference between (280 Hz, 3 μm) and (50 Hz, 16 μm) circular orbital excitations, and no directional difference, with thrombus formation of 2.5 times longer under all conditions than that without excitation.

conclusionIn the case of simple reciprocating excitation, the time was approximately 1.2 times longer. This indicated that the circular orbital excitation is more effective.

Indexed as

Heart-Assist DevicesThrombosisAnimalsCentrifugationEquipment DesignProsthesis DesignSwineWhole Blood Coagulation Timeantithrombogenicitycircular orbitintelligent functionmagnetic bearingvibration of impeller