Evidence map›Paper›PMID 36304794›Full record

ArticleFrontiers in robotics and AI2022

Towards Autonomous Robotic Minimally Invasive Ultrasound Scanning and Vessel Reconstruction on Non-Planar Surfaces.

Nils Marahrens, Bruno Scaglioni, Dominic Jones, Raj Prasad, Chandra Shekhar Biyani, Pietro Valdastri

Open access · goldAbstract read
In one paragraph

Article in Frontiers in robotics and AI, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 2 pooled it
1.1field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 2 syntheses or guidelines pooled it, 14 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. A Minimally Invasive Robotic Tissue Palpation Device.IEEE transactions on bio-medical engineering · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Nils MarahrensStorm Lab UK, Institute for Robotics, Autonomous Systems and Sensing, School of Electronic and Electrical Engineering, University of Leeds, Leeds, United Kingdom.
Bruno ScaglioniStorm Lab UK, Institute for Robotics, Autonomous Systems and Sensing, School of Electronic and Electrical Engineering, University of Leeds, Leeds, United Kingdom.
Dominic JonesStorm Lab UK, Institute for Robotics, Autonomous Systems and Sensing, School of Electronic and Electrical Engineering, University of Leeds, Leeds, United Kingdom.
Raj PrasadDepartment for Hepatobiliary Surgery, James's University Hospital, Leeds Teachings Hospitals NHS Trust, Leeds, United Kingdom.
Chandra Shekhar BiyaniDepartment for Urology, James's University Hospital, Leeds Teachings Hospitals NHS Trust, Leeds, United Kingdom.
Pietro ValdastriStorm Lab UK, Institute for Robotics, Autonomous Systems and Sensing, School of Electronic and Electrical Engineering, University of Leeds, Leeds, United Kingdom.
University of Leeds · GBLeeds Teaching Hospitals NHS Trust · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Autonomous robotic Ultrasound (US) scanning has been the subject of research for more than 2 decades. However, little work has been done to apply this concept into a minimally invasive setting, in which accurate force sensing is generally not available and robot kinematics are unreliable due to the tendon-driven, compliant robot structure. As a result, the adequate orientation of the probe towards the tissue surface remains unknown and the anatomy reconstructed from scan may become highly inaccurate. In this work we present solutions to both of these challenges: an attitude sensor fusion scheme for improved kinematic sensing and a visual, deep learning based algorithm to establish and maintain contact between the organ surface and the US probe. We further introduce a novel scheme to estimate and orient the probe perpendicular to the center line of a vascular structure. Our approach enables, for the first time, to autonomously scan across a non-planar surface and navigate along an anatomical structure with a robotically guided minimally invasive US probe. Our experiments on a vessel phantom with a convex surface confirm a significant improvement of the reconstructed curved vessel geometry, with our approach strongly reducing the mean positional error and variance. In the future, our approach could help identify vascular structures more effectively and help pave the way towards semi-autonomous assistance during partial hepatectomy and the potential to reduce procedure length and complication rates.

Indexed as

anatomy based navigationautonomous robotic ultrasoundnon-planar scan surfacerobotic surgerytissue coupling estimationvessel reconstruction

Identifiers

PMID36304794
PMCPMC9594548
OpenAlexW4304187370

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.