Evidence map›Paper›PMID 36302647›Full record

ArticleJournal of periodontal & implant science2022

Thermal changes during implant site preparation with a digital surgical guide and slot design drill: an

Yoon-Sil Choi, Jae-Woon Oh, Young Lee, Dong-Woon Lee

Open access · hybridAbstract read
In one paragraph

Article in Journal of periodontal & implant science, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Yoon-Sil ChoiDepartment of Periodontology, Veterans Health Service Medical Center, Seoul, Korea.ORCID https://orcid.org/0000-0002-7918-7669
Jae-Woon OhDepartment of Periodontology, Veterans Health Service Medical Center, Seoul, Korea.ORCID https://orcid.org/0000-0002-0526-1512
Young LeeVeterans Medical Research Institute, Veterans Health Service Medical Center, Seoul, Korea.ORCID https://orcid.org/0000-0003-0178-0187
Dong-Woon LeeDepartment of Periodontology, Veterans Health Service Medical Center, Seoul, Korea.ORCID https://orcid.org/0000-0002-0796-9100
Veterans Health Service Medical Center · KR

Funding

Korea Government KMDF_PR_20200901_0238VHS Medical Center VHSMC 20036
6 · The paper itself

Abstract

purposeIn this study, we aimed to evaluate the degree of heat generation when a novel drill design with an irrigation slot was used with metal sleeve-free (MF) and metal sleeve-incorporated (MI) surgical guides in an environment similar to that of the actual oral cavity.

methodsA typodont with a missing mandibular right first molar and 21 bovine rib blocks were used. Three-dimensional-printed MF and MI surgical guides, designed for the placement of internal tapered implant fixtures, were used with slot and non-slot drills. The following groups were compared: group 1, MI surgical guide with slot drill; group 2, MI surgical guide with a non-slot drill; and group 3, MF surgical guide with a slot drill. A constant-temperature water bath at 36°C was used. The drilling was performed in 6 stages, and the initial, highest, and lowest temperatures of the cortical bone were measured at each stage using a non-contact infrared thermometer.

resultsThere were no temperature increases above the initial temperature in any drilling procedure. The only significant difference between the non-slot and slot groups was observed with the use of the first drill in the MI group, with a higher temperature in the non-slot group (

conclusionsWithin the limitations of this study, implant-site preparation with the surgical guide showed no critical increase in the temperature of the cortical bone, regardless of whether there was a slot in the drill. In particular, the slotted drill had a cooling effect during the initial drilling.

Indexed as

Cortical boneDental implantsIn vitro techniquesOsteonecrosisThermometers

Identifiers

PMID36302647
PMCPMC9614178
OpenAlexW4285293562

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.