Evidence map›Paper›PMID 36300872›Full record

ArticleJournal of applied clinical medical physics2022

Statistical process control to monitor use of a web-based autoplanning tool.

Hunter Mehrens, Raphael Douglas, Mary Gronberg, Kelly Nealon, Joy Zhang, Laurence Court

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Statistical process control to monitor use of a web-based autoplanning tool.Journal of applied clinical medical physics · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hunter MehrensDepartment of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
Raphael DouglasDepartment of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
Mary GronbergDepartment of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
Kelly NealonDepartment of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
Joy ZhangDepartment of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
Laurence CourtDepartment of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.

Funding

NRSA Training CoreTL1TR003169 · NCATS · UNIVERSITY OF TEXAS HLTH SCI CTR HOUSTON · PI CHANDRA, JOYA, FROST, JEFFREY A. · 2019 to 2023
$3.7M
NCATS NIH HHS TL1 TR003169
6 · The paper itself

Abstract

purposeTo investigate the use of statistical process control (SPC) for quality assurance of an integrated web-based autoplanning tool, Radiation Planning Assistant (RPA).

methodsAutomatically generated plans were downloaded and imported into two treatment planning systems (TPSs), RayStation and Eclipse, in which they were recalculated using fixed monitor units. The recalculated plans were then uploaded back to the RPA, and the mean dose differences for each contour between the original RPA and the TPSs plans were calculated. SPC was used to characterize the RPA plans in terms of two comparisons: RayStation TPS versus RPA and Eclipse TPS versus RPA for three anatomical sites, and variations in the machine parameters dosimetric leaf gap (DLG) and multileaf collimator transmission factor (MLC-TF) for two algorithms (Analytical Anisotropic Algorithm [AAA]) and Acuros in the Eclipse TPS. Overall, SPC was used to monitor the process of the RPA, while clinics would still perform their routine patient-specific QA.

resultsFor RayStation, the average mean percent dose differences across all contours were 0.65% ± 1.05%, -2.09% ± 0.56%, and 0.28% ± 0.98% and average control limit ranges were 1.89% ± 1.32%, 2.16% ± 1.31%, and 2.65% ± 1.89% for the head and neck, cervix, and chest wall, respectively. In contrast, Eclipse's average mean percent dose differences across all contours were -0.62% ± 0.34%, 0.32% ± 0.23%, and -0.91% ± 0.98%, while average control limit ranges were 1.09% ± 0.77%, 3.69% ± 2.67%, 2.73% ± 1.86%, respectively. Averaging all contours and removing outliers, a 0% dose difference corresponded with a DLG value of 0.202 ± 0.019 cm and MLC-TF value of 0.020 ± 0.001 for Acuros and a DLG value of 0.135 ± 0.031 cm and MLC-TF value of 0.015 ± 0.001 for AAA.

conclusionsDifferences in mean dose and control limits between RPA and two separately commissioned TPSs were determined. With varying control limits and means, SPC provides a flexible and useful process quality assurance tool for monitoring a complex automated system such as the RPA.

Indexed as

Radiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedAlgorithmsHumansInternetRadiometryRadiotherapy Dosageautocontouringdose verificationstatistical process control

Identifiers

PMID36300872
PMCPMC9797174

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.