Evidence map›Paper›PMID 36300870›Full record

ArticleJournal of applied clinical medical physics2022

Treatment planning with a 2.5 MV photon beam for radiation therapy.

Navid Khaledi, Chris Hayes, Louise Belshaw, Mark Grattan, Rao Khan, James L Gräfe

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.9field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Treatment planning with a 2.5 MV photon beam for radiation therapy.Journal of applied clinical medical physics · 2022
    Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 4 countries.

Navid KhalediDepartment of Physics, Faculty of Science, Toronto Metropolitan University, Toronto, Ontario, Canada.
Chris HayesRadiotherapy Physics, Northern Ireland Cancer Centre, Belfast Health and Social Care Trust, Belfast, UK.
Louise BelshawRadiotherapy Physics, Northern Ireland Cancer Centre, Belfast Health and Social Care Trust, Belfast, UK.
Mark GrattanRadiotherapy Physics, Northern Ireland Cancer Centre, Belfast Health and Social Care Trust, Belfast, UK.
Rao KhanDepartment of Physics, Faculty of Science, Toronto Metropolitan University, Toronto, Ontario, Canada.
James L GräfeDepartment of Physics, Faculty of Science, Toronto Metropolitan University, Toronto, Ontario, Canada.
Belfast Health and Social Care Trust · GBMetropolitan University · RSToronto Metropolitan University · CAUniversity of Toronto · CA

Funding

Natural Sciences and Engineering Research Council of CanadaToronto Metropolitan University
6 · The paper itself

Abstract

purposeThe shallow depth of maximum dose and higher dose fall-off gradient of a 2.5 MV beam along the central axis that is available for imaging on linear accelerators is investigated for treatment of shallow tumors and sparing the organs at risk (OARs) beyond it. In addition, the 2.5 MV beam has an energy bridging the gap between kilo-voltage (kV) and mega-voltage (MV) beams for applications of dose enhancement with high atomic number (Z) nanoparticles.

methodsWe have commissioned and utilized a MATLAB-based, open-source treatment planning software (TPS), matRad, for intensity-modulated radiation therapy (IMRT) dose calculations. Treatment plans for prostate, liver, and head and neck (H&N), nasal cavity, two orbit cases, and glioblastoma multiforme (GBM) were performed and compared to a conventional 6 MV beam. Additional Monte Carlo calculations were also used for benchmarking the central axis dose.

resultsBoth beams had similar planning target volume (PTV) dose coverage for all cases. However, the 2.5 MV beam deposited 6%-19% less integral doses to the nasal cavity, orbit, and GBM cases than 6 MV photons. The mean dose to the heart in the liver plan was 10.5% lower for 2.5 MV beam. The difference between the doses to OARs of H&N for two beams was under 3%. Brain mean dose, brainstem, and optic chiasm max doses were, respectively, 7.5%-14.9%, 2.2%-8.1%, and 2.5%-19.0% lower for the 2.5 MV beam in the nasal cavity, orbit, and GBM plans.

conclusionsThis study demonstrates that the 2.5 MV beam can produce clinically relevant treatment plans, motivating future efforts for design of single-energy LINACs. Such a machine will be capable of producing beams at this energy beneficial for low- and middle-income countries, and investigations on dose enhancement from high-Z nanoparticles.

Indexed as

Radiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedHumansMaleMonte Carlo MethodPhotonsRadiotherapy DosageSoftware2.5 MV photonscommissioningIMRTMonte Carlo simulationradiotherapytreatment planning

Identifiers

PMID36300870
PMCPMC9797178
OpenAlexW4307425461

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.