ArticleMagnetic resonance in medicine2023
Average saturation efficiency filter ASEF-CEST MRI of stroke rodents.
Article in Magnetic resonance in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Quantitative Consistency of Amide Proton Transfer-Weighted MRI for Brain Tumor Differentiation: Systematic Review of Clinical Evidence.Tomography (Ann Arbor, Mich.) · 2026Pooled it
- High-Temporal-Resolution Monitoring of Creatine and Phosphocreatine Dynamics in Skeletal Muscle Using Ultrafast Z-Spectroscopy (UFZ) CEST MRI at 3T.Magnetic resonance in medicine · 2026Article
- Mitochondrial oxidative phosphorylation capacity in skeletal muscle measured by ultrafast Z-spectroscopy (UFZ) MRI at 3T.Magnetic resonance in medicine · 2025Article
- Improving standardization and accuracy of in vivo omega plot exchange parameter determination using rotating-frame model-based fitting of quasi-steady-state Z-spectra.Magnetic resonance in medicine · 2025Article
- A rapid method for phosphocreatine-weighted imaging in muscle using double saturation power-chemical exchange saturation transfer.NMR in biomedicine · 2024Article
- Specific and rapid guanidinium CEST imaging using double saturation power and QUASS analysis in a rodent model of global ischemia.Magnetic resonance in medicine · 2024Article
- Adjustment of rotation and saturation effects (AROSE) for CEST imaging.Magnetic resonance in medicine · 2024Article
- Validation of the presence of fast exchanging amine CEST effect at low saturation powers and its influence on the quantification of APT.Magnetic resonance in medicine · 2023Article
- Radiofrequency labeling strategies in chemical exchange saturation transfer MRI.NMR in biomedicine · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
purposeThe average saturation efficiency filter (ASEF) is a novel method of improving the specificity of CEST; however, there is a mismatch between the magnetization transfer (MT) effect under high-duty cycle and low-duty cycle pulse trains. We explore measures of mitigation and the sensitivity and potential of ASEF imaging in phantoms and stroke rats.
methodsSimulation and nicotinamide phantoms in denatured protein were used to investigate the effect of different average saturation powers and MT pool parameters on matching coefficients used for correction as well as the ASEF ratio signal and baseline. Then, in vivo studies were performed in stroke rodents to further investigate the sensitivity and fidelity of ASEF ratio spectra.
resultsSimulation and studies of nicotinamide phantoms show that the matching coefficient needed to correct the baseline MT mismatch is strongly dependent on the average saturation power. In vivo studies in stroke rodents show that the matching coefficient required to correct the baseline MT mismatch is different for normal versus ischemic tissue. Thus, a baseline correction was performed to further suppress the residue MT mismatch. After correction of the mismatch, ASEF ratio achieved comparable contrast at 3.6 ppm between normal and ischemic tissue when compared to the apparent amide proton transfer (APT*) approach. Moreover, contrasts for 2.0 and 2.6 ppm were also ascertainable from the same spectra.
conclusionASEF can improve the CEST signal specificity of slow exchange labile protons such as amide and guanidyl, with small loss to sensitivity. It has strong potential in the CEST imaging of various diseases.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.