Evidence map›Paper›PMID 36300851›Full record

ArticleMagnetic resonance in medicine2023

Average saturation efficiency filter ASEF-CEST MRI of stroke rodents.

Julius Juhyun Chung, Tao Jin

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Julius Juhyun ChungDepartment of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania.ORCID 0000-0002-1513-5181
Tao JinDepartment of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania.ORCID 0000-0003-2912-3517

Funding

Magnetic Resonance Imaging of Glucose Analogs in StrokeR01NS100703 · NINDS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI JIN, TAO · 2018 to 2022
$1.6M
NIH HHS NS100703NINDS NIH HHS R01 NS100703
6 · The paper itself

Abstract

purposeThe average saturation efficiency filter (ASEF) is a novel method of improving the specificity of CEST; however, there is a mismatch between the magnetization transfer (MT) effect under high-duty cycle and low-duty cycle pulse trains. We explore measures of mitigation and the sensitivity and potential of ASEF imaging in phantoms and stroke rats.

methodsSimulation and nicotinamide phantoms in denatured protein were used to investigate the effect of different average saturation powers and MT pool parameters on matching coefficients used for correction as well as the ASEF ratio signal and baseline. Then, in vivo studies were performed in stroke rodents to further investigate the sensitivity and fidelity of ASEF ratio spectra.

resultsSimulation and studies of nicotinamide phantoms show that the matching coefficient needed to correct the baseline MT mismatch is strongly dependent on the average saturation power. In vivo studies in stroke rodents show that the matching coefficient required to correct the baseline MT mismatch is different for normal versus ischemic tissue. Thus, a baseline correction was performed to further suppress the residue MT mismatch. After correction of the mismatch, ASEF ratio achieved comparable contrast at 3.6 ppm between normal and ischemic tissue when compared to the apparent amide proton transfer (APT*) approach. Moreover, contrasts for 2.0 and 2.6 ppm were also ascertainable from the same spectra.

conclusionASEF can improve the CEST signal specificity of slow exchange labile protons such as amide and guanidyl, with small loss to sensitivity. It has strong potential in the CEST imaging of various diseases.

Indexed as

RodentiaStrokeAmidesAnimalsMagnetic Resonance ImagingNiacinamideProtonsRatsAmidesNiacinamideProtonsASEFCESTexchange rate filteringmatching coefficientMCAO

Identifiers

PMID36300851
PMCPMC9757140

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.