Position of different nebulizer types for aerosol delivery in an adult model of mechanical ventilation.

Haijia Hou, Dongyang Xu, Bing Dai, Hongwen Zhao, Wei Wang, Jian Kang, Wei Tan

Abstract read
In one paragraph

Article in Frontiers in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Observational
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. AnFrontiers in medicine · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Haijia HouDepartment of Respiratory and Critical Care Medicine, The First Hospital of China Medical University, Shenyang, China.
Dongyang XuDepartment of Respiratory and Critical Care Medicine, The First Hospital of China Medical University, Shenyang, China.
Bing DaiDepartment of Respiratory and Critical Care Medicine, The First Hospital of China Medical University, Shenyang, China.
Hongwen ZhaoDepartment of Respiratory and Critical Care Medicine, The First Hospital of China Medical University, Shenyang, China.
Wei WangDepartment of Respiratory and Critical Care Medicine, The First Hospital of China Medical University, Shenyang, China.
Jian KangDepartment of Respiratory and Critical Care Medicine, The First Hospital of China Medical University, Shenyang, China.
Wei TanDepartment of Respiratory and Critical Care Medicine, The First Hospital of China Medical University, Shenyang, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The optimal positions of different types of nebulizer for aerosol delivery remain unclear. Methods: Three ICU ventilators employing three types of nebulizer were separately connected to a simulated lung to simulate nebulization during invasive ventilation. Assist/control-pressure control (A/C-PC) mode was utilized, with inspiratory pressure (Pi) set to 12 cmH Results: The aerosol delivery of c-JN, i-JN, and VMN was 5.33 ± 0.49~11.12 ± 0.36%, 7.73 ± 0.76~13.75 ± 0.46% and 11.13 ± 56-30.2 ± 1.63%, respectively. The higher aerosol delivery: for c-JN~Positions 2 (10.95 ± 0.15%), fori-JN~Positions 1 or 2 (12.91 ± 0.88% or 13.45 ± 0.42%), for VMN~Positions 4(29.03 ± 1.08%); the lower aerosol delivery: for c-JN~Positions 1, 3 or 5, fori-JN~Positions 4 or 5, for VMN~Positions 5.The highest aerosol delivery:For c-JN at Position 2 (10.95 ± .15%), for i-JN at Position 1 or 2 (12.91 ± .88% or 13.45 ± .42%), for VMN at Positions 4 (29. 03 ± 1.08%); the lower aerosol delivery: for c-JN at Positions 1, 3 or 5, for i-JN at Positions 4 or 5, for VMN at Positions 5. The highest aerosol deliveryof c-JN was lower than that of i-JN while the VMN was the highest (all Conclusion: During adult mechanical ventilation, the type and position of nebulizer influences aerosol delivery efficiency, with no differences between ventilators.

Indexed as

aerosol deliveryinspiratory synchronizedjet nebulizerpositionvibrating mesh nebulizer