Article in Photoacoustics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
23 citing papers in PubMed.
- Acquisition-inspired motion artifact modeling and degradation-consistent diffusion restoration in photoacoustic microscopy.Photoacoustics · 2026Article
- Fully integrated photoacoustic microscopy for multi-scale and longitudinal imaging in translational biomedical applications.Biomedical optics express · 2026Article
- Development of a Dual Photoacoustic-Ultrasound Imaging System: Current Status and Future Perspectives.Sensors (Basel, Switzerland) · 2026Review
- A handheld photoacoustic microscopic probe integrating a transparent ultrasound transducer and a fiber scanner.Nature communications · 2025Article
- GPU-accelerated volumetric-mosaic optical-resolution photoacoustic microscopy and quantifying tumor vasculature growth.Photoacoustics · 2025Article
- High-frequency (> 65 MHz) broadband transparent transducer with ultrathin gold electrode for dual-mode photoacoustic and laser-induced ultrasound microscopy.Photoacoustics · 2025Article
- A comprehensive review of high-performance photoacoustic microscopy systems.Photoacoustics · 2025Review
- Wavelength-time-division multiplexed fiber-optic sensor array for wide-field photoacoustic microscopy.Photoacoustics · 2025Article
- Transparent ultrasonic transducers based on relaxor ferroelectric crystals for advanced photoacoustic imaging.Nature communications · 2024Article
- Investigation of an Active Focusing Planar Piezoelectric Ultrasonic Transducer.Sensors (Basel, Switzerland) · 2024Article
- An ultrasensitive and broadband transparent ultrasound transducer for ultrasound and photoacoustic imaging in-vivo.Nature communications · 2024Article
- Sounding out the dynamics: a concise review of high-speed photoacoustic microscopy.Journal of biomedical optics · 2024Review
- Photoacoustic imaging plus X: a review.Journal of biomedical optics · 2024Review
- High speed innovations in photoacoustic microscopy.Npj imaging · 2024Review
- Tailored photoacoustic apertures with superimposed optical holograms.Biomedical optics express · 2023Article
- Broadband transparent ultrasound transducer with polymethyl methacrylate as matching layer forPhotoacoustics · 2023Article
- Editorial: Breaking the speed limits in photoacoustic microscopy.Photoacoustics · 2023Article
- Multiscale photoacoustic tomography using reversibly switchable thermochromics.Journal of biomedical optics · 2023Article
- Functional photoacoustic imaging: from nano- and micro- to macro-scale.Nano convergence · 2023Review
- Homogeneous-resolution photoacoustic microscopy for ultrawide field-of-view neurovascular imaging in Alzheimer's disease.Photoacoustics · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
Combining focused optical excitation and high-frequency ultrasound detection, optical-resolution photoacoustic microscopy (OR-PAM) can provide micrometer-level spatial resolution with millimeter-level penetration depth and has been employed in a variety of biomedical applications. However, it remains a challenge for OR-PAM to achieve a high imaging speed and a large field of view at the same time. In this work, we report a new approach to implement high-speed wide-field OR-PAM, using a cylindrically-focused transparent ultrasound transducer (CFT-UT). The CFT-UT is made of transparent lithium niobate coated with indium-tin-oxide as electrodes. A transparent cylindrical lens is attached to the transducer surface to provide an acoustic focal line with a length of 9 mm. The excitation light can pass directly through the CFT-UT from the above and thus enables a reflection imaging mode. High-speed imaging is achieved by fast optical scanning of the focused excitation light along the CFT-UT focal line. With the confocal alignment of the optical excitation and acoustic detection, a relatively high detection sensitivity is maintained over the entire scanning range. The CFT-UT-based OR-PAM system has achieved a cross-sectional frame rate of 500 Hz over the scanning range of 9 mm. We have characterized the system's performance on phantoms and demonstrated its application on small animal models in vivo. We expect the new CFT-UT-based OR-PAM will find matched biomedical applications that need high imaging speed over a large field of view.