Evidence map›Paper›PMID 36298431›Full record

ArticleSensors (Basel, Switzerland)2022

Polarization Calibration of a Microwave Polarimeter with Near-Infrared Up-Conversion for Optical Correlation and Detection.

Francisco J Casas, Patricio Vielva, R Belen Barreiro, Enrique Martínez-González, G Pascual-Cisneros

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Francisco J CasasInstituto de Física de Cantabria (IFCA), Avda. Los Castros s/n, 39005 Santander, Spain.ORCID 0000-0002-2217-5843
Patricio VielvaInstituto de Física de Cantabria (IFCA), Avda. Los Castros s/n, 39005 Santander, Spain.ORCID 0000-0003-0051-272X
R Belen BarreiroInstituto de Física de Cantabria (IFCA), Avda. Los Castros s/n, 39005 Santander, Spain.ORCID 0000-0002-6139-4272
Enrique Martínez-GonzálezInstituto de Física de Cantabria (IFCA), Avda. Los Castros s/n, 39005 Santander, Spain.ORCID 0000-0002-0179-8590
G Pascual-CisnerosInstituto de Física de Cantabria (IFCA), Avda. Los Castros s/n, 39005 Santander, Spain.ORCID 0000-0002-1653-1549
Instituto de Física de Cantabria · ES

Funding

Agencia Estatal de Investigación (AEI) ESP2017-92135-EXP, ESP2017-83921-C2-1-R, AYA2017-90675-REDC, PID2019-110610RB-C21/AEI/10.13039/501100011033, MDM-2017-0765
6 · The paper itself

Abstract

This paper presents a polarization calibration method applied to a microwave polarimeter demonstrator based on a near-infrared (NIR) frequency up-conversion stage that allows both optical correlation and signal detection at a wavelength of 1550 nm. The instrument was designed to measure the polarization of cosmic microwave background (CMB) radiation from the sky, obtaining the Stokes parameters of the incoming signal simultaneously, in a frequency range from 10 to 20 GHz. A linearly polarized input signal with a variable polarization angle is used as excitation in the polarimeter calibration setup mounted in the laboratory. The polarimeter systematic errors can be corrected with the proposed calibration procedure, achieving high levels of polarization efficiency (low polarization percentage errors) and low polarization angle errors. The calibration method is based on the fitting of polarization errors by means of sinusoidal functions composed of additive or multiplicative terms. The accuracy of the fitting increases with the number of terms in such a way that the typical error levels required in low-frequency CMB experiments can be achieved with only a few terms in the fitting functions. On the other hand, assuming that the calibration signal is known with the required accuracy, additional terms can be calculated to reach the error levels needed in ultrasensitive B-mode polarization CMB experiments.

Indexed as

astronomycalibrationcosmic microwave backgroundinstrumentationpolarizationsystematic errors

Identifiers

PMID36298431
PMCPMC9609977
OpenAlexW4307319331

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.