ArticleSensors (Basel, Switzerland)2022
Multi-Center Evaluation of Gel-Based and Dry Multipin EEG Caps.
Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- A systematic evaluation of EEG electrode geometry for enhanced signals: an experimental approach.Scientific reports · 2026Article
- Electroencephalography for early Alzheimer's disease diagnosis: from advanced feature engineering to interpretable ai and clinical translation.Frontiers in psychiatry · 2026Review
- Neonatal Electroencephalogram Recording with a Dry Electrode Cap: A Feasibility Study.Sensors (Basel, Switzerland) · 2025Article
- Article
- Implementation of mobile EEG for resting-state and visual evoked potentials in young children in rural Ethiopia.Frontiers in human neuroscience · 2025Article
- Reliability of brain metrics derived from a Time-Domain Functional Near-Infrared Spectroscopy System.Scientific reports · 2024Article
- Simultaneous Dry and Gel-Based High-Density Electroencephalography Recordings.Sensors (Basel, Switzerland) · 2023Article
- Flower electrodes for comfortable dry electroencephalography.Scientific reports · 2023Article
- A Film Electrode upon Nanoarchitectonics of Bacterial Cellulose and Conductive Fabric for Forehead Electroencephalogram Measurement.Sensors (Basel, Switzerland) · 2023Article
- Development of Low-Contact-Impedance Dry Electrodes for Electroencephalogram Signal Acquisition.Sensors (Basel, Switzerland) · 2023Article
- An ecological study protocol for the multimodal investigation of the neurophysiological underpinnings of dyadic joint action.Frontiers in human neuroscience · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
Abstract
Dry electrodes for electroencephalography (EEG) allow new fields of application, including telemedicine, mobile EEG, emergency EEG, and long-term repetitive measurements for research, neurofeedback, or brain-computer interfaces. Different dry electrode technologies have been proposed and validated in comparison to conventional gel-based electrodes. Most previous studies have been performed at a single center and by single operators. We conducted a multi-center and multi-operator study validating multipin dry electrodes to study the reproducibility and generalizability of their performance in different environments and for different operators. Moreover, we aimed to study the interrelation of operator experience, preparation time, and wearing comfort on the EEG signal quality. EEG acquisitions using dry and gel-based EEG caps were carried out in 6 different countries with 115 volunteers, recording electrode-skin impedances, resting state EEG and evoked activity. The dry cap showed average channel reliability of 81% but higher average impedances than the gel-based cap. However, the dry EEG caps required 62% less preparation time. No statistical differences were observed between the gel-based and dry EEG signal characteristics in all signal metrics. We conclude that the performance of the dry multipin electrodes is highly reproducible, whereas the primary influences on channel reliability and signal quality are operator skill and experience.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.