Evidence map›Paper›PMID 36298307›Full record

ArticleSensors (Basel, Switzerland)2022

Real-Time Detection and Classification of Power Quality Disturbances.

Mahsa Mozaffari, Keval Doshi, Yasin Yilmaz

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Mahsa MozaffariElectrical Engineering Department, University of South Florida, Tampa, FL 33620, USA.ORCID 0000-0001-5898-8224
Keval DoshiElectrical Engineering Department, University of South Florida, Tampa, FL 33620, USA.
Yasin YilmazElectrical Engineering Department, University of South Florida, Tampa, FL 33620, USA.ORCID 0000-0003-2014-3060

Funding

National Science Foundation 2040572
6 · The paper itself

Abstract

This paper considers the problem of real-time detection and classification of power quality disturbances in power delivery systems. We propose a sequential and multivariate disturbance detection method (aiming for quick and accurate detection). Our proposed detector follows a non-parametric and supervised approach, i.e., it learns nominal and anomalous patterns from training data involving clean and disturbance signals. The multivariate nature of the method enables joint processing of data from multiple meters, facilitating quicker detection as a result of the cooperative analysis. We further extend our supervised sequential detection method to a multi-hypothesis setting, which aims to classify the disturbance events as quickly and accurately as possible in a real-time manner. The multi-hypothesis method requires a training dataset per hypothesis, i.e., per each disturbance type as well as the 'no disturbance' case. The proposed classification method is demonstrated to quickly and accurately detect and classify power disturbances.

Indexed as

Algorithmsanomaly detectionnon-parametric sequential methodspower quality disturbancessequential multi-hypothesis testingsmart grid

Identifiers

PMID36298307
PMCPMC9608145

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.