Evidence map›Paper›PMID 36298219›Full record

ArticleSensors (Basel, Switzerland)2022

Developing Disposable EEG Cap for Infant Recordings at the Neonatal Intensive Care Unit.

Amirreza Asayesh, Elina Ilen, Marjo Metsäranta, Sampsa Vanhatalo

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Amirreza AsayeshBABA Center, Pediatric Research Center, Department of Clinical Neurophysiology and Pediatrics, Children's Hospital and HUS Imaging, Helsinki University Central Hospital, HUS, 00029 Helsinki, Finland.
Elina IlenDepartment of Design, Aalto University, 02150 Espoo, Finland.
Marjo MetsärantaBABA Center, Pediatric Research Center, Department of Clinical Neurophysiology and Pediatrics, Children's Hospital and HUS Imaging, Helsinki University Central Hospital, HUS, 00029 Helsinki, Finland.
Sampsa VanhataloBABA Center, Pediatric Research Center, Department of Clinical Neurophysiology and Pediatrics, Children's Hospital and HUS Imaging, Helsinki University Central Hospital, HUS, 00029 Helsinki, Finland.ORCID 0000-0002-9771-7061

Funding

European Union's Horizon 2020 research and innovation program under the Marie Sklodowska 813483
6 · The paper itself

Abstract

Long-term EEG monitoring in neonatal intensive care units (NICU) is challenged with finding solutions for setting up and maintaining a sufficient recording quality with limited technical experience. The current study evaluates different solutions for the skin-electrode interface and develops a disposable EEG cap for newborn infants. Several alternative materials for the skin-electrode interface were compared to the conventional gel and paste: conductive textiles (textured and woven), conductive Velcro, sponge, super absorbent hydrogel (SAH), and hydro fiber sheets (HF). The comparisons included the assessment of dehydration and recordings of signal quality (skin interphase impedance and powerline (50 Hz) noise) for selected materials. The test recordings were performed using snap electrodes integrated into a forearm sleeve or a forehead band along with skin-electrode interfaces to mimic an EEG cap with the aim of long-term biosignal recording on unprepared skin. In the hydration test, conductive textiles and Velcro performed poorly. While the SAH and HF remained sufficiently hydrated for over 24 h in an incubator-mimicking environment, the sponge material was dehydrated during the first 12 h. Additionally, the SAH was found to have a fragile structure and was electrically prone to artifacts after 12 h. In the electrical impedance and recording comparisons of muscle activity, the results for thick-layer HF were comparable to the conventional gel on unprepared skin. Moreover, the mechanical instability measured by 1-2 Hz and 1-20 Hz normalized relative power spectrum density was comparable with clinical EEG recordings using subdermal electrodes. The results together suggest that thick-layer HF at the skin-electrode interface is an effective candidate for a preparation-free, long-term recording, with many advantages, such as long-lasting recording quality, easy use, and compatibility with sensitive infant skin contact.

Indexed as

ElectroencephalographyIntensive Care Units, NeonatalArtifactsElectric ImpedanceElectrodesHumansHydrogelsInfantInfant, NewbornHydrogelsaEEGHFNICUSAH

Identifiers

PMID36298219
PMCPMC9607480

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.