Evidence map›Paper›PMID 36297885›Full record

ReviewPolymers2022

A Review of Biomaterials and Associated Performance Metrics Analysis in Pre-Clinical Finite Element Model and in Implementation Stages for Total Hip Implant System.

Md Mohiuddin Soliman, Muhammad E H Chowdhury, Mohammad Tariqul Islam, Farayi Musharavati, Mohammad Nabil, Muhammad Hafizh, Amith Khandakar, Sakib Mahmud, Erfan Zal Nezhad, Md Nazmul Islam Shuzan and 1 more

Open access · goldAbstract readReview
In one paragraph

Review in Polymers, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
5.7field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 30 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Review
  6. Review
  7. Article
  8. Review
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 3 institutions in 3 countries.

Md Mohiuddin SolimanDepartment of Electrical, Electronic & Systems Engineering, Universiti Kebangsaan Malaysia, Bangi 43600, Selangor, Malaysia.ORCID 0000-0002-0268-9978
Muhammad E H ChowdhuryDepartment of Electrical Engineering, Qatar University, Doha 2713, Qatar.ORCID 0000-0003-0744-8206
Mohammad Tariqul IslamCentre for Advanced Electronic and Communication Engineering, Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering & Built Environment, Universiti Kebangsaan Malaysia (UKM), Bangi 43600, Selangor, Malaysia.ORCID 0000-0002-4929-3209
Farayi MusharavatiDepartment of Mechanical & Industrial Engineering, Qatar University, Doha 2713, Qatar.ORCID 0000-0003-0489-0090
Mohammad NabilDepartment of Electrical Engineering, Qatar University, Doha 2713, Qatar.
Muhammad HafizhDepartment of Mechanical & Industrial Engineering, Qatar University, Doha 2713, Qatar.ORCID 0000-0002-9550-5321
Amith KhandakarDepartment of Electrical Engineering, Qatar University, Doha 2713, Qatar.ORCID 0000-0001-7068-9112
Sakib MahmudDepartment of Electrical Engineering, Qatar University, Doha 2713, Qatar.ORCID 0000-0002-4599-2192
Erfan Zal NezhadDepartment of Biomedical Engineering, University of Texas at San Antonio, San Antonio, TX 78249, USA.
Md Nazmul Islam ShuzanDepartment of Electrical, Electronic & Systems Engineering, Universiti Kebangsaan Malaysia, Bangi 43600, Selangor, Malaysia.ORCID 0000-0002-3089-9737
Farhan Fuad AbirDepartment of Electrical Engineering, Qatar University, Doha 2713, Qatar.ORCID 0000-0001-7203-5876
Qatar University · QANational University of Malaysia · MYThe University of Texas at San Antonio · US

Funding

Qatar National Research Fund NPRP11S-0102-180178
6 · The paper itself

Abstract

Total hip replacement (THR) is a common orthopedic surgery technique that helps thousands of individuals to live normal lives each year. A hip replacement replaces the shattered cartilage and bone with an implant. Most hip implants fail after 10-15 years. The material selection for the total hip implant systems is a major research field since it affects the mechanical and clinical performance of it. Stress shielding due to excessive contact stress, implant dislocation due to a large deformation, aseptic implant loosening due to the particle propagation of wear debris, decreased bone remodeling density due to the stress shielding, and adverse tissue responses due to material wear debris all contribute to the failure of hip implants. Recent research shows that pre-clinical computational finite element analysis (FEA) can be used to estimate four mechanical performance parameters of hip implants which are connected with distinct biomaterials: von Mises stress and deformation, micromotion, wear estimates, and implant fatigue. In vitro, in vivo, and clinical stages are utilized to determine the hip implant biocompatibility and the unfavorable local tissue reactions to different biomaterials during the implementation phase. This research summarizes and analyses the performance of the different biomaterials that are employed in total hip implant systems in the pre-clinical stage using FEA, as well as their performances in in vitro, in vivo, and in clinical studies, which will help researchers in gaining a better understanding of the prospects and challenges in this field.

Indexed as

biocompatibilityfinite element analysismicromotionstress distributiontotal hip implantwear

Identifiers

PMID36297885
PMCPMC9607025
OpenAlexW4306153345

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.