Evidence map›Paper›PMID 36296733›Full record

ArticleMolecules (Basel, Switzerland)2022

Development and Optimization of a New UPLC-UV/MS Method through DoE and MLR for Detecting Substandard Drug Products to Treat Tuberculosis.

Javier Suárez-González, Amor R Cáceres-Pérez, Alexis Oliva, Ana Santoveña-Estévez, José B Fariña

Open access · goldAbstract read
In one paragraph

Article in Molecules (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 88% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Javier Suárez-GonzálezDepartamento de Ingeniería Química y Tecnología Farmacéutica, Facultad de Farmacia, Universidad de La Laguna, 38200 San Cristóbal de La Laguna, Spain.ORCID 0000-0002-9900-3169
Amor R Cáceres-PérezDepartamento de Ingeniería Química y Tecnología Farmacéutica, Facultad de Farmacia, Universidad de La Laguna, 38200 San Cristóbal de La Laguna, Spain.
Alexis OlivaDepartamento de Ingeniería Química y Tecnología Farmacéutica, Facultad de Farmacia, Universidad de La Laguna, 38200 San Cristóbal de La Laguna, Spain.ORCID 0000-0002-4661-4257
Ana Santoveña-EstévezDepartamento de Ingeniería Química y Tecnología Farmacéutica, Facultad de Farmacia, Universidad de La Laguna, 38200 San Cristóbal de La Laguna, Spain.ORCID 0000-0002-3424-7824
José B FariñaDepartamento de Ingeniería Química y Tecnología Farmacéutica, Facultad de Farmacia, Universidad de La Laguna, 38200 San Cristóbal de La Laguna, Spain.
Universidad de La Laguna · ES

Funding

Cooperation Programme Interreg V-A MAC 2014-2020, MAC2/1.1a/219
6 · The paper itself

Abstract

Drug products used for treating tuberculosis are one of the most widely reported medicines to be classified as falsified or substandard in low- and middle-income countries, representing a major hazard to health. The aim of this study was, firstly, to develop an ultra-performance liquid chromatography (UPLC) method which is able to analyze fixed combination tablets with up to four active pharmaceutical ingredients, including isoniazid, pyrazinamide, rifampicin, and ethambutol. Secondly, we aimed to optimize it through the design of experiments and multi-linear regression based on a central composite design and to validate it according to the guidelines of the International Conference on Harmonization. The application of this tools enabled the identification of the influential factors (flow rate, formic acid, and temperature) and their effects on the studied responses (retention factor and percentage for each drug) as part of the quality by design approach. The method proved to be to be linear in the range from 5.0 to 15 µg/mL for isoniazid, pyrazinamide, and rifampicin, being precise (<1%) and accurate (97−101%). In addition, the method validated for ethambutol proved to be linear from 1.4 to 4.2 µg/mL, as well as precise (0.54%) and accurate (97.3%). The method was stability indicated for all the active pharmaceutical ingredients studied and was able to detect two substandard formulations sampled on the African market.

Indexed as

Substandard DrugsTuberculosisAntitubercular AgentsChromatography, LiquidEthambutolHumansIsoniazidPyrazinamideRifampinTabletsAntitubercular AgentsEthambutolIsoniazidPyrazinamideRifampinSubstandard DrugsTabletscentral composite designdesign of experimentmulti-linear regressionquality by designtuberculosis

Identifiers

PMID36296733
PMCPMC9610718
OpenAlexW4307262089

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.