ArticleMicromachines2022
Design and High-Resolution Analysis of an Efficient Periodic Split-and-Recombination Microfluidic Mixer.
Article in Micromachines, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Developing Micro/Nanostructured Fluidic Mixing Technology for Biomedical Applications.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
We developed a highly efficient passive mixing device based on a split-and-recombine (SAR) configuration. This micromixer was constructed by simply bonding two identical microfluidic periodical open-trench patterns face to face. The structure parameters of periodical units were optimized through numerical simulation to facilitate the mixing efficiency. Despite the simplicity in design and fabrication, it provided rapid mixing performance in both experiment and simulation conditions. To better illustrate the mixing mechanism, we developed a novel scheme to achieve high-resolution confocal imaging of serial channel cross-sections to accurately characterize the mixing details and performance after each SAR cycle. Using fluorescent IgG as an indicator, nearly complete mixing was achieved using only four SAR cycles in an aqueous solution within a device's length of less than 10 mm for fluids with a Péclet number up to 8.7 × 10
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.